DOI 10.1088/0031-9155/50/9/005

Медицинская библиотека · Physics in medicine and biology · 2005

Dosimetric accuracy of a staged radiosurgery treatment.

Cernica George, de Boer Steven F, Diaz Aidnag, Fenstermaker Robert A, Podgorsak Matthew B

Оценочное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

For large cerebral arteriovenous malformations (AVMs), the efficacy of radiosurgery is limited since the large doses necessary to produce obliteration may increase the risk of radiation necrosis to unacceptable levels. An alternative is to stage the radiosurgery procedure over multiple stages (usually two), effectively irradiating a smaller volume of the AVM nidus with a therapeutic dose during each session. The difference between coordinate systems defined by sequential stereotactic frame placements can be represented by a translation and a rotation. A unique transformation can be determined based on the coordinates of several fiducial markers fixed to the skull and imaged in each stereotactic coordinate system. Using this transformation matrix, isocentre coordinates from the first stage can be displayed in the coordinate system of subsequent stages allowing computation of a combined dose distribution covering the entire AVM. The accuracy of this approach was tested on an anthropomorphic head phantom and was verified dosimetrically. Subtle defects in the phantom were used as control points, and 2 mm diameter steel balls attached to the surface were used as fiducial markers and reference points. CT images (2 mm thick) were acquired. Using a transformation matrix developed with two frame placements, the predicted locations of control and reference points had an average error of 0.6 mm near the fiducial markers and 1.0 mm near the control points. Dose distributions in a staged treatment approach were accurately calculated using the transformation matrix. This approach is simple, fast and accurate. Errors were small and clinically acceptable for Gamma Knife radiosurgery. Accuracy can be improved by reducing the CT slice thickness.

Для цитирования: Cernica George, de Boer Steven F, Diaz Aidnag, Fenstermaker Robert A, Podgorsak Matthew B. Dosimetric accuracy of a staged radiosurgery treatment.. Physics in medicine and biology. 2005. DOI: 10.1088/0031-9155/50/9/005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.