Ultrasonographic measurement of the distal femoral cartilage thickness in patients with unilateral transtibial amputation.

Akkaya Nuray, Akkaya Semih, Özçakar Levent, Demirkan Fahir, Kiter Esat, Konukcu Sibel, Ardic Fusun

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Lower limb amputation sometimes predisposes to degenerative secondary disorders.

OBJECTIVES

To evaluate the distal femoral cartilage thicknesses of patients with unilateral transtibial amputations using ultrasound and to investigate the relationship between cartilage thickness and disease-related parameters.

STUDY

DESIGN

Cross-sectional study.

METHODS

Twenty-four unilateral transtibial amputees (mean age: 46.4 ± 8.5 years, range: 28-60 years) were evaluated. Duration of prosthesis use (years) and daily walking time with prosthesis (hours) were recorded. Functional status was assessed by gate velocity (m/s), and 6-min walking distance (m) with prosthesis. Ultrasound was used to measure distal femoral cartilage thicknesses bilaterally at medial/lateral condyles and the intercondylar areas. The percentages of cartilage loss (of the amputee-side in comparison with the nonamputee-side) were calculated.

RESULTS

Compared to the nonamputee-sides, distal femoral cartilage was significantly thinner at lateral condyles and the intercondylar areas on the amputee-sides (p < 0.05). Significant positive correlations were detected between the percentage of cartilage loss (at all three sites of measurement) and gate velocity, 6-min walking distance, and daily walking time with prosthesis (all p < 0.05).

CONCLUSIONS

Future prospective controlled studies are warranted to determine the principles of optimum prosthetic use regarding its possible effects on the femoral cartilage of amputee patients.

CLINICAL RELEVANCE: The correlations between the cartilage loss in the amputee extremity with faster gait and longer daily prosthetic use suggest that abnormal gait patterns might increase the loading on the amputated extremity.

Для цитирования: Akkaya Nuray, Akkaya Semih, Özçakar Levent, Demirkan Fahir, Kiter Esat, Konukcu Sibel, Ardic Fusun. Ultrasonographic measurement of the distal femoral cartilage thickness in patients with unilateral transtibial amputation.. Prosthetics and orthotics international. 2012. DOI: 10.1177/0309364612464233.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.