MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ahj.2014.07.023

Медицинская библиотека · American heart journal · 2014

Causes and timing of death during long-term follow-up after transcatheter aortic valve replacement.

Saia Francesco, Latib Azeem, Ciuca Cristina, Gasparetto Valeria, Napodano Massimo, Sticchi Alessandro, Anderlucci Laura, Marrozzini Cinzia, Naganuma Toru, Alfieri Ottavio, Facchin Michela, Hoxha Brunilda, Moretti Carolina, Marzocchi Antonio, Colombo Antonio, Tarantini Giuseppe

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) is an effective therapeutic option for patients with severe aortic stenosis at high risk for surgery. Identification of causes of death after TAVR may help improve patient selection and outcome.

METHODS

We enrolled 874 consecutive patients who underwent TAVR at 3 centers using all approved bioprostheses and different access routes. Clinical outcomes during follow-up were defined according to the Valve Academic Research Consortium 2 definitions. Causes of deaths were carefully investigated.

RESULTS

Mean logistic European System for Cardiac Operative Risk Evaluation was 23.5% ± 15.3%; Society of Thoracic Surgery score, 9.0% ± 8.2%. The Corevalve (Medtronic, Minneapolis, MN) was used in 41.3%; the Edwards Sapien (Edwards Lifesciences Inc., Irvine, CA) in 57.3%. Vascular access was transfemoral in 75.7%. In-hospital mortality was 5.0%. Cumulative mortality rates at 1 to 3 years were 12.4%, 23.4%, and 31.5%, respectively. Landmark analysis showed a significantly higher incidence of cardiovascular (CV) death in the first 6 months of follow-up and a significantly higher incidence of non-CV death thereafter. At Cox regression analysis, the independent predictors of in-hospital mortality were acute kidney injury grades 2 to 3 (hazard ratio [HR] 3.41) life-threatening bleeding (HR 4.26), major bleeding (HR 4.61), and myocardial infarction (HR 3.89). The independent predictors of postdischarge mortality were chronic obstructive pulmonary disease (HR 1.48), left ventricular ejection fraction at discharge (HR 0.98), and glomerular filtration rate <30 mL/min per 1.73 m(2) (HR 1.64).

CONCLUSIONS

Around a third of patients treated with TAVR in daily practice die within the first 3 years of follow-up. Early mortality is predominantly CV, whereas late mortality is mainly non-CV, and it is often due to preexisting comorbidity.

Для цитирования: Saia Francesco, Latib Azeem, Ciuca Cristina, Gasparetto Valeria, Napodano Massimo, Sticchi Alessandro, Anderlucci Laura, Marrozzini Cinzia, Naganuma Toru, Alfieri Ottavio, Facchin Michela, Hoxha Brunilda, Moretti Carolina, Marzocchi Antonio, Colombo Antonio, Tarantini Giuseppe. Causes and timing of death during long-term follow-up after transcatheter aortic valve replacement.. American heart journal. 2014. DOI: 10.1016/j.ahj.2014.07.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.