MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2007.07.015

Медицинская библиотека · The Journal of hand surgery · 2007

A comparison of polyglycolic acid versus type 1 collagen bioabsorbable nerve conduits in a rat model: an alternative to autografting.

Waitayawinyu Thanapong, Parisi Debra M, Miller Brian, Luria Shai, Morton Holly J, Chin Simon H, Trumble Thomas E

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Severe nerve injury with segmental loss requires nerve graft or conduit repair. We compared 2 synthetic, bioabsorbable nerve conduits with the gold standard of autogenous nerve grafting using histopathologic and neurophysiologic analyses.

METHODS

A 10-mm segment of the sciatic nerve of 45 Sprague-Dawley rats was resected, leaving a gap defect. Three experimental groups were used: 15 coaptations using type I collagen nerve conduits, 15 coaptations using polyglycolic acid (PGA) nerve conduits, and 15 coaptations using the excised segments as autogenous nerve grafts. The contralateral legs were used as unoperated controls. After 15 weeks, nerve regeneration was evaluated by measuring isometric muscle contraction force, axonal counting, wet muscle weights, and histology.

RESULTS

Statistically significant differences in the isometric muscle contraction force, axonal counts, and wet muscle weights were found between type I collagen conduit and nerve graft compared to the PGA conduit. Axonal sprouting was less organized and less dense with the PGA conduits when compared to nerve reconstruction with the type I collagen conduits and nerve grafts.

CONCLUSIONS

Type I collagen conduits and autografts produced comparable results, which were significantly better than PGA conduits. The use of type I collagen conduit is a reliable alternative to nerve grafting for gaps up to 10 mm in length.

Для цитирования: Waitayawinyu Thanapong, Parisi Debra M, Miller Brian, Luria Shai, Morton Holly J, Chin Simon H, Trumble Thomas E. A comparison of polyglycolic acid versus type 1 collagen bioabsorbable nerve conduits in a rat model: an alternative to autografting.. The Journal of hand surgery. 2007. DOI: 10.1016/j.jhsa.2007.07.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.