Environment international · 2016
Volatile organic compounds of possible microbial origin and their risks on childhood asthma and allergies within damp homes.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Choi Hyunok, Schmidbauer Norbert, Bornehag Carl-Gustaf
Аннотация
BACKGROUND: Risk of indoor exposure to volatile organic compounds of purported microbial origin on childhood symptoms of wheezing, rhinitis, and/or eczema, and doctor-diagnosed asthma, rhinitis, and eczema, respectively, remain unclear.
OBJECTIVE: To test hypotheses that total sum of 28 microbial volatile organic compounds (Σ26 MVOCs): 1) poses independent risk on doctor-diagnosed asthma, rhinitis, and eczema, respectively, as well as multiple symptom presentation with a minimum of the two of the above conditions (i.e. case); 2) is associated with significant interaction with absolute humidity (AH) on additive scale.
METHODS: In a case-control investigation, 198 cases and 202 controls were examined during November 2001 - March 2002 period through home indoor air sampling, air quality inspection, and health outcome ascertainment.
RESULTS: Not only the Σ28 MVOCs but also the global MVOC index were significantly higher within the homes of the cases with a high AH, compared to the controls with a low AH (all Ps<0.001). Only the cases, but not the controls, were associated with a dose-dependent increase in the exposure variables of interest (Σ28 MVOCs) per quartile increase in AH (P<0.0001 for the cases; P=0.780 for the controls). Only among the children who live in a high AH homes, a natural log (ln)-unit of Σ 28 MVOCs was associated with 2.5-times greater odds of the case status (95% CI, 1.0-6.2; P=0.046), compared to 0.7-times the odds (95% CI, 0.4-1.0; P=0.074) of the same outcome among the low AH homes. Specifically, joint exposure to a high MVOCs and high AH was associated with 2.6-times greater odds of the doctor-diagnosed asthma status (95% CI, 0.7-8.91; P=0.137).
CONCLUSION: Joint occurrence of high Σ28 MVOCs and AH was associated with a significant increase in the case status and asthma risks in an additive scale.
OBJECTIVE: To test hypotheses that total sum of 28 microbial volatile organic compounds (Σ26 MVOCs): 1) poses independent risk on doctor-diagnosed asthma, rhinitis, and eczema, respectively, as well as multiple symptom presentation with a minimum of the two of the above conditions (i.e. case); 2) is associated with significant interaction with absolute humidity (AH) on additive scale.
METHODS: In a case-control investigation, 198 cases and 202 controls were examined during November 2001 - March 2002 period through home indoor air sampling, air quality inspection, and health outcome ascertainment.
RESULTS: Not only the Σ28 MVOCs but also the global MVOC index were significantly higher within the homes of the cases with a high AH, compared to the controls with a low AH (all Ps<0.001). Only the cases, but not the controls, were associated with a dose-dependent increase in the exposure variables of interest (Σ28 MVOCs) per quartile increase in AH (P<0.0001 for the cases; P=0.780 for the controls). Only among the children who live in a high AH homes, a natural log (ln)-unit of Σ 28 MVOCs was associated with 2.5-times greater odds of the case status (95% CI, 1.0-6.2; P=0.046), compared to 0.7-times the odds (95% CI, 0.4-1.0; P=0.074) of the same outcome among the low AH homes. Specifically, joint exposure to a high MVOCs and high AH was associated with 2.6-times greater odds of the doctor-diagnosed asthma status (95% CI, 0.7-8.91; P=0.137).
CONCLUSION: Joint occurrence of high Σ28 MVOCs and AH was associated with a significant increase in the case status and asthma risks in an additive scale.