MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.archger.2019.02.004

Медицинская библиотека · Archives of gerontology and geriatrics · 2019

The feasibility of a vision-based sensor for longitudinal monitoring of mobility in older adults with dementia.

Dolatabadi Elham, Zhi Ying Xuan, Flint Alastair J, Mansfield Avril, Iaboni Andrea, Taati Babak

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Gait and balance functions decline through the course of dementia, and can serve as a marker of changes in physical status and falls risk. We have developed a technology (AMBIENT), based on a vision-based sensor, which enables the frequent, accurate, and unobtrusive measurement of gait and balance.

OBJECTIVE

The objective of this study was to examine the feasibility of using AMBIENT technology for frequent assessment of mobility in people with dementia within an inpatient setting. In particular, we examined technical feasibility, and the feasibility of participant recruitment, data collection and analysis.

METHODS

AMBIENT was installed in a specialized dementia inpatient unit. AMBIENT captured gait bouts as the participants walked within the view of the sensor during their daily routine and computed the spatiotemporal parameters of gait.

RESULTS

Twenty participants (age: 76.9 ± 6.7 years, female: 50%) were recruited over a period of 6 months. We recorded a total of 3843 gait bouts, of which 1171 could be used to extract gait data. On average, 58 ± 47 walking sequences per person were collected over a recording period of 28 ± 20 days. We were able to consistently extract six quantitative parameters of gait, consisting of stride length, stride time, cadence, velocity, step length asymmetry, and step time asymmetry.

SIGNIFICANCE: This study demonstrates the feasibility of longitudinal tracking of gait in a dementia inpatient setting. This technology has important potential applications in monitoring functional status over time, and the development of dynamic falls risk assessments.

Для цитирования: Dolatabadi Elham, Zhi Ying Xuan, Flint Alastair J, Mansfield Avril, Iaboni Andrea, Taati Babak. The feasibility of a vision-based sensor for longitudinal monitoring of mobility in older adults with dementia.. Archives of gerontology and geriatrics. 2019. DOI: 10.1016/j.archger.2019.02.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.