Melting curve analysis reveals false-positive norovirus detection in a molecular syndromic panel.

Matic Nancy, Lawson Tanya, Young Matthew, Jang Willson, Bilawka Jennifer, Gowland Leah, Ritchie Gordon, Leung Victor, Payne Michael, Stefanovic Aleksandra, Romney Marc G, Lowe Christopher F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Molecular syndromic panels can improve rapidity of results and ease clinical laboratory workflow, although caution has been raised for potential false-positive results. Upon implementation of a new panel for infectious diarrhea (BioFire® FilmArray® Gastrointestinal [GI] Panel, bioMérieux) in our clinical laboratory, a higher than expected number of stool samples with norovirus were detected.

OBJECTIVES

The goal of this study was to investigate positive percent agreement and the false-positive rate of norovirus detected by the multiplex BioFire GI panel compared to a singleplex commercial assay.

STUDY

DESIGN

From October 2023 to January 2024, all prospective stool samples with a positive norovirus result by BioFire had melting curves reviewed manually using the BioFire FilmArray Torch System. Stool samples further underwent testing by a supplementary real-time RT-PCR assay (Xpert® Norovirus, Cepheid) for comparative analysis.

RESULTS

Of the 50 stool samples with norovirus detected by BioFire, 18 (36 %) tested negative by Xpert (deemed "false-positives"). Furthermore, melting curve analysis revealed nearly all of these samples had atypical melting curve morphologies for the "Noro-1" target on BioFire (16/18, 89 %), which was statistically significant (Odds Ratio 173.2, 95 % CI [22.2, 5326.9], p < 0.0001). Stool samples with multiple pathogens detected by BioFire including norovirus were not more likely to produce false-positive norovirus results (Odds Ratio 1, 95 % CI [0.3, 3.3], p = 1).

CONCLUSIONS

Although not described in the manufacturer's Instructions for Use, we propose routine manual review of melting curves for the BioFire GI panel prior to reporting, to mitigate potential false-positive norovirus results.

Для цитирования: Matic Nancy, Lawson Tanya, Young Matthew, Jang Willson, Bilawka Jennifer, Gowland Leah, Ritchie Gordon, Leung Victor, Payne Michael, Stefanovic Aleksandra, Romney Marc G, Lowe Christopher F. Melting curve analysis reveals false-positive norovirus detection in a molecular syndromic panel.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2024. DOI: 10.1016/j.jcv.2024.105697.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.