m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2023

Development and validation of a multiplex HPLC-MS/MS assay for the monitoring of JAK inhibitors in patient plasma.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tachet Jérémie, Versace François, Mercier Thomas, Buclin Thierry, Decosterd Laurent A, Choong Eva, Girardin François R

Аннотация

Janus kinase inhibitors (JAKi) are oral small molecules used in the treatment of a broad spectrum of autoimmune and myeloproliferative diseases. JAKi exhibit significant intra- and inter-individual pharmacokinetic variabilities, due to fluctuations in compliance with oral treatments and their metabolism essentially driven by cytochrome P450 enzymes. Intrinsically, JAKi have dose-response relationship and narrow therapeutic index: therapeutic drug monitoring (TDM) is expected to optimize and adapt their dosage regimen in order to resolve problems of efficacy and tolerance linked to dose and safety. A sensitive analytical method using multiplex high-performance liquid-chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) was developed and validated for the simultaneous quantification in plasma of the 6 major currently used JAKi, namely abrocitinib, baricitinib, fedratinib, ruxolitinib, tofacitinib, and upadacitinib. Plasma samples are subjected to protein precipitation with MeOH, using stable isotopically labelled internal standards. The separation of JAKi in supernatants diluted 1:1 with ultrapure H2O was performed using a C18 column Xselect HSS T3 2.5 µm, 2.1x150 mm using a mobile phase composed of formic acid (FA) 0.2% and acetonitrile (+FA 0.1%) in gradient mode. The analytical run time for the multiplex assay was 7 min. JAKi drugs were monitored by electrospray ionization in the positive mode followed by triple-stage quadrupole MS/MS analysis. The method was validated according to SFSTP and ICH guidelines over the clinically relevant concentration ranges (0.5-200 ng/mL for abrocitinib, baricitinib and upadacitinib; 1-400 ng/mL for tofacitinib; 0.5-400 ng/mL for ruxolitinib, and 10-800 ng/mL for fedratinib). This multiplex HPLC-MS/MS assay achieved good performances in term of trueness (91.1-113.5%), repeatability (3.0-9.9%), and intermediate precision (4.5-11.3%). We developed and validated a highly sensitive method for the multiplex quantification of the JAKi abrocitinib, baricitinib, fedratinib, ruxolitinib, tofacitinib, and upadacitinib in human plasma. The method will be applied for prospective clinical pharmacokinetic studies to determine whether TDM programs for JAKi based on residual drug concentrations can be recommended using disease-specific therapeutic ranges.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты