MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.12062

Медицинская библиотека · Artificial organs · 2013

Complication profile of the Berlin Heart EXCOR biventricular support in children.

Schweiger Martin, Schrempf Julia, Sereinigg Michael, Prenner Günther, Tscheliessnigg Karlheinz H, Wasler Andre, Krumnikel Jacub, Gamillschegg Andreas, Knez Igor

СтатьяПеревод в очереди

Аннотация

In chronic cardiomyopathy, mechanical circulatory support (MCS) plays an increasingly important role for children as the shortage of suitable donor hearts increases waiting time on the transplant list. We report our experience with the paracorporal Berlin Heart EXCOR System (Berlin Heart AG, Berlin, Germany) used as a biventricuclar assist device (BVAD). Nine patients with a BVAD EXCOR system were treated between 2006 and 2012; out of these patients, four were less than 18 years old (6, 14, 14, and 17 years old). Their diagnoses were postcardotomy failure (n = 1), dilatative cardiomyopathy (n = 2), and terminal heart failure (n = 1). Overall survival, waiting time for heart transplantation (HTx) and complication profile for the BVAD were analyzed retrospectively. Thirty days' mortality was 25% (n = 1). One child died after 84 days on support due to cerebral bleeding. Mean support time was 218.75 days (4, 84, 262, and 525 days). Pump chamber exchange was necessary three times due to pump chamber thrombosis (n = 2) and partial pump chamber membrane rupture (n = 1). Complications included: sepsis (n = 1), drive line infection requiring intravenous antibiotics (n = 2), and recurrent epistaxis (n = 3). Two children were successfully transplanted after 262/525 days on BVAD; they are currently at home (follow-up: 1.9 and 2.3 years). The EXCOR is a life-saving MCS system suitable for long-term paracorporeal biventricular assistance.

Для цитирования: Schweiger Martin, Schrempf Julia, Sereinigg Michael, Prenner Günther, Tscheliessnigg Karlheinz H, Wasler Andre, Krumnikel Jacub, Gamillschegg Andreas, Knez Igor. Complication profile of the Berlin Heart EXCOR biventricular support in children.. Artificial organs. 2013. DOI: 10.1111/aor.12062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.