MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3113/fai.2007.1183

Медицинская библиотека · Foot & ankle international · 2007

Fixation of calcaneal avulsion fractures using screws with and without suture anchors: a biomechanical investigation.

Khazen Gabriel E, Wilson Adam N, Ashfaq Sarmad, Parks Brent G, Schon Lew C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Lag screw fixation commonly is used to treat avulsion fractures of the posterior calcaneal tuberosity, but this method may not offer reliable fixation. This study compared the strength to failure of lag screws compared to lag screw fixation augmented with suture anchors in these fractures.

METHODS

The calcanei and Achilles tendons of 12 fresh lower extremity cadaver matched pairs were dissected and removed. An oblique osteotomy was created in the calcaneus, and two 4.0-mm lag screws were placed nearly perpendicular to the plane of the fracture in the dorsal aspect of the calcaneus with 30 degrees of divergence between them. In the contralateral specimen, the same procedure was done, but with two suture anchors placed 1.5 to 2 mm distal to the osteotomy. A zigzag suture technique through the Achilles tendon was used. The specimens were mounted and placed in a load frame for monotonic loading to failure. A paired Student t-test and a Pearson correlation were used to analyze the data (p <or= 0.05).

RESULTS

The specimens treated with lag screws alone failed at 251.3 (range 66 to 459) N whereas specimens repaired with lag screws and suture anchors failed at 441.6 (range 274 to 661; p = 0.01 N).

CONCLUSIONS

Suture anchor augmentation significantly improved the strength of screw fixation of the calcaneal posterior tuberosity avulsion fractures.

CLINICAL RELEVANCE: The use of suture anchor augmentation as described may improve the reliability of fixation in avulsion fractures of the posterior calcaneal tuberosity.

Для цитирования: Khazen Gabriel E, Wilson Adam N, Ashfaq Sarmad, Parks Brent G, Schon Lew C. Fixation of calcaneal avulsion fractures using screws with and without suture anchors: a biomechanical investigation.. Foot & ankle international. 2007. DOI: 10.3113/fai.2007.1183.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.