MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajem.2023.05.009

Медицинская библиотека · The American journal of emergency medicine · 2023

Evaluation of electronic measurement of capillary refill for Sepsis screening at ED triage.

Hansen Matthew, Gillespie Jordan, Riddick Tyne, Samatham Ravi, Baker Steven, Filer Scott, Xin Haichang, Sheridan David

Наблюдательное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the association between capillary refill time (CRT) measured by a medical device and sepsis among patients presenting to the Emergency Department (ED).

METHODS

This prospective observational study enrolled adult and pediatric patients during ED triage when sepsis was considered a potential diagnosis by the triage nurse. Patients were enrolled at an academic medical center between December 2020 and June 2022. CRT was measured by a research assistant using an investigational medical device. The outcomes included sepsis and septic shock defined using sep-3 criteria, septic shock defined as IV antibiotics and a vasopressor requirement, ICU admission, and hospital mortality. Other measures included patient demographics and vital signs at ED triage. We evaluated univariate associations between CRT and sepsis outcomes.

RESULTS

We enrolled 563 patients in the study, 48 met Sep-3 criteria, 5 met Sep-3 shock criteria, and 11 met prior septic shock criteria (IV antibiotics and vasopressors to maintain mean arterial pressure of 65). Sixteen patients were admitted to the ICU. The mean age was 49.1 years, and 51% of the cohort was female. The device measured CRT was significantly associated with the diagnosis of sepsis by sep-3 criteria (OR 1.23, 95% CI 1.06-1-43), septic shock by sep-3 criteria (OR 1.57, 95% CI 1.02-2.40), and septic shock defined as receipt of IV antibiotics and a vasopressor requirement (OR 1.37, 95% CI 1.03-1.82). Patients with CRT >3.5 s measured by the DCR device had an odds ratio of 4.67 (95%CI 1.31-16.1) of septic shock (prior definition), and an odds ratio of 3.97 (95% CI 1.99-7.92) of ICU admission, supporting the potential for the 3.5-s cutoff of the DCR measurement.

CONCLUSIONS

CRT measured by a medical device at ED triage was associated with the diagnosis of sepsis. Objective CRT measurement using a medical device may be a relatively simple way to improve sepsis diagnosis during ED triage.

Для цитирования: Hansen Matthew, Gillespie Jordan, Riddick Tyne, Samatham Ravi, Baker Steven, Filer Scott, Xin Haichang, Sheridan David. Evaluation of electronic measurement of capillary refill for Sepsis screening at ED triage.. The American journal of emergency medicine. 2023. DOI: 10.1016/j.ajem.2023.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.