The international journal of cardiovascular imaging · 2020
Diagnostic accuracy of regadenoson stress echocardiography: concordance with gated-spect myocardial perfusion imaging.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Iglesias-Garriz Ignacio, Vara-Manso Javier, Sevilla Ana, Corral Felix, Lastra Jose A, Rodríguez Eladio, Garrote Carmen, Del Castillo Samuel, de la Fuente Carmen, Fernandez-Vazquez Felipe
Аннотация
Regadenoson Stress Echocardiography (RSE) can detect myocardial ischemia, and its diagnostic accuracy should be evaluated. We sought to investigate the agreement between RSE and gated-SPECT myocardial perfusion imaging (MPI) and appraise its diagnostic accuracy. Consecutive patients (n = 202) referred for non-invasive evaluation of myocardial ischemia, with (38.6%) or without a previous coronary artery disease (CAD) diagnosis, were enrolled. Both tests were performed simultaneously. Invasive coronary angiography (CA) is considered the gold standard. The mean age was 70.9 (9.8) years, and 59.9% were male. The prevalence of cardiovascular risk factors (arterial hypertension [81.7%], diabetes mellitus [37.6%], hypercholesterolemia [71.8%], and smoking [18.8%]) was high. Forty-four patients (21.8%) had a non-interpretable electrocardiogram, 15 (34.1%) of them were a result of ventricular paced-rhythm, while 29 (65.9%) were a result of advanced left ventricular branch block. The overall agreement between both diagnostic techniques was good: Gwet's AC1 0.66 (CI95% 0.55 to 0.76), and it was higher in patients without a previous CAD diagnosis: 0.76 (CI95% 0.65 to 0.87). In the biased sample (those who underwent CA), RSE and nuclear study sensitivity was 0.50 and 0.78 and specificity was 0.75 and 0.75, respectively. We noted a dramatic reduction in sensitivity for RSE after debiasing (debiased sensitivity of 0.16), and the negative predictive value was similar to the biased and debiased samples. RSE is in strong agreement with gated-SPECT MPI. However, its low sensitivity and negative predictive value preclude its use as a bedside test to detect myocardial ischemia.
Предметные рубрики MeSH
AgedCardiac-Gated Imaging TechniquesComorbidityEchocardiography, StressFemaleHeart Disease Risk FactorsHumansMaleMiddle AgedMyocardial IschemiaMyocardial Perfusion ImagingOrganophosphorus CompoundsOrganotechnetium CompoundsPredictive Value of TestsPrevalencePurinesPyrazolesRadiopharmaceuticalsReproducibility of ResultsSmokingTechnetium Tc 99m SestamibiTomography, Emission-Computed, Single-PhotonVasodilator Agents