m+Medelevator.RU
← Поиск публикаций
Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2014

Evaluation of velopharyngeal closure by 4D imaging using 320-detector-row computed tomography.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sakamoto Yoshiaki, Soga Shigeyoshi, Jinzaki Masahiro, Yamada Yoshitake, Ogata Hisao, Kishi Kazuo

Аннотация

OBJECTIVE: Current imaging techniques for velopharyngeal closure (VPC) evaluation are two-dimensional, static, or distressing, thus necessitating multiple procedures to understand this three-dimensional and dynamic area. We validated the use of a novel four-dimensional (4D) computed tomography (CT) technique for the morphological and kinematic evaluation of VPC in cleft palate patients based on dynamic volume scanning with 320-detector-row CT.

METHODS: Five patients aged 4-10 years (40% males) with persistent velopharyngeal insufficiency post palatoplasty underwent conventional tests (cephalometry and video-nasal endoscopy) and 4D-CT. For each patient, complete multiplanar reconstruction, 4D airway CT, and 4D-CT endoscopy data for all scanning phases were compared with cephalometric and video-nasal endoscopy data. The movements of the velum and posterior pharyngeal walls were graded by each modality.

RESULTS: 4D airway CT revealed higher anatomical detail than cephalometry, additionally providing dynamic images. 4D-CT endoscopy and video-nasal endoscopy were in agreement for all patients regarding the patterns of VPC, with complete visualization of VPC in five versus one patient, respectively. 4D airway CT and cephalometry showed a discrepancy in one case, wherein grading by cephalometry was overestimated. 4D-CT was also useful in determining the width and length of a proposed pharyngeal flap. The examination time (mean ± standard deviation (SD), seconds), including patient preparation time, was 224 ± 73, 492 ± 145, and 718 ± 123 for cephalometric radiographs, CT, and video-nasal endoscopy, respectively. The mean estimated radiation dose during 4D-CT was 4.44 ± 1.64 mSv.

CONCLUSIONS: 4D-CT provides detailed morphological and kinematic analysis of VPC and may offer advantages over conventional procedures.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты