m+Medelevator.RU
← Поиск публикаций
Journal of clinical monitoring and computing · 2018

Reliability of effective arterial elastance using peripheral arterial pressure as surrogate for left ventricular end-systolic pressure.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Monge Garcia Manuel Ignacio, Jian Zhongping, Settels Jos J, Hatib Feras, Cecconi Maurizio, Pinsky Michael R

Аннотация

To compare the effective arterial elastance (Ea) obtained from the arterial pressure with Ea calculated from left-ventricular (LV) pressure-volume analysis. Experimental study. LV pressure-volume data was obtained with a conductance catheter and arterial pressures were measured via a fluid-filled catheter placed in the proximal aorta, femoral and radial arteries. Ea was calculated as LV end-systolic pressure (ESP)/stroke volume (SV). Experimental protocol consisted sequentially changing afterload (phenylephrine/nitroprusside), preload (bleeding/fluid), and contractility (esmolol/dobutamine). 90% of systolic pressure (Eaao_SYS, Eafem_SYS, Earad_SYS), mean arterial pressure (Eaao_MAP, Eafem_MAP, Earad_MAP), and dicrotic notch pressure (Eaao_DIC, Eafem_DIC, Earad_DIC) were used as surrogates for LV ESP. SV was calculated from the LV pressure-volume data. When Ea was compared with estimations based on 90% SAP, the relationship was r2 = 0.95, 0.94 and 0.92; and the bias and limits of agreement (LOA): - 0.01 ± 0.12, - 0.09 ± 0.12, - 0.05 ± 0.15 mmHg ml-1, for Eaao_SYS, Eafem_SYS and Earad_SYS, respectively. For estimates using dicrotic notch, the relationship was r2 = 0.94, 0.95 and 0.94 for Eaao_DIC, Eafem_DIC and Earad_DIC, respectively; with a bias and LOA: 0.05 ± 0.11, 0.06 ± 0.12, 0.10 ± 0.12 mmHg ml-1, respectively. When Ea was compared with estimates using MAP, the relationship was r2 = 0.95, 0.96 and 0.95 for Eaao_MAP, Eafem_MAP and Earad_MAP, respectively; with a bias and LOA: 0.05 ± 0.11, 0.06 ± 0.11, 0.06 ± 0.11 mmHg ml-1, respectively. LV ESP can be estimated from the arterial pressure. Provided that the SV measurement is reliable, the ratio MAP/SV provides a robust Ea surrogate over a wide range of hemodynamic conditions and is interchangeably in any peripheral artery, so it should be recommended as an arterial estimate of Ea in further research.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты