Insulin Pumps in Type 1 Diabetes with Mental Disorders: Real-Life Clinical Data Indicate Discrepancies to Recommendations.

Prinz Nicole, Bächle Christina, Becker Marianne, Berger Gabriele, Galler Angela, Haberland Holger, Meusers Michael, Mirza Joaquina, Plener Paul L, von Sengbusch Simone, Thienelt Michaela, Holl Reinhard W, DPV Initiative

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The latest American Association of Clinical Endocrinologists/American College of Endocrinologists consensus statement published in 2014 does not recommend continuous subcutaneous insulin infusion (CSII) in patients with mental health problems. This study investigated the use and discontinuation of CSII in daily routine care of type 1 diabetes (T1D) patients with or without comorbid mental disorders.

MATERIALS AND

METHODS

Insulin-treated T1D patients (n = 48,700) between 5 and 30 years of age (median [interquartile range], 15.6 [12.0-17.7] years) from the German/Austrian diabetes patient follow-up registry (DPV) were studied. A comorbid diagnosis and/or specific treatment of mental disorder was documented in 3,158 (6.5%) patients: attention-deficit hyperactivity disorder (ADHD), n = 1,352; depression, n = 692; eating disorders, n = 395; needle phobia, n = 319; anxiety/obsessive compulsive disorder (OCD), n = 231; and psychosis and/or neuroleptic medication, n = 169. Multivariable logistic regression with age, sex, diabetes duration, and migration background as independent variables was used to compare groups.

RESULTS

After adjustment for confounders, use of CSII was more common in patients with depression (41.5%), anxiety/OCD (41.4%), or needle phobia (75.8%) compared with patients without mental disorders (34.6%) (each P < 0.05). By contrast, psychotic patients (26.2%, P < 0.05) used CSII less often, and patients with ADHD (36.3%) or eating disorders (33.9%) used it with a similar frequency. Compared with patients without mental disorders (5.1%), the rate of CSII discontinuation was higher in patients with ADHD (9.7%), depression (8.2%), or eating disorders (10.0%) (P < 0.05, respectively) but similar in patients with anxiety/OCD (6.0%), psychosis (4.2%), or needle phobia (5.3%).

CONCLUSIONS

In routine diabetes care, CSII use and discontinuation vary widely among T1D patients with mental disorders and indicate clear differences from the latest recommendations.

Для цитирования: Prinz Nicole, Bächle Christina, Becker Marianne, Berger Gabriele, Galler Angela, Haberland Holger, Meusers Michael, Mirza Joaquina, Plener Paul L, von Sengbusch Simone, Thienelt Michaela, Holl Reinhard W, DPV Initiative. Insulin Pumps in Type 1 Diabetes with Mental Disorders: Real-Life Clinical Data Indicate Discrepancies to Recommendations.. Diabetes technology & therapeutics. 2015. DOI: 10.1089/dia.2015.0180.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.