MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.11-1972

Медицинская библиотека · Chest · 2011

Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades.

O'Connell Oisin J, McWilliams Sebastian, McGarrigle AnneMarie, O'Connor Owen J, Shanahan Fergus, Mullane David, Eustace Joseph, Maher Michael M, Plant Barry J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

With the increasing life expectancy for patients with cystic fibrosis (CF), and a known predisposition to certain cancers, cumulative radiation exposure from radiologic imaging is of increasing significance. This study explores the estimated cumulative effective radiation dose over a 17-year period from radiologic procedures and changing trends of imaging modalities over this period.

METHODS

Estimated cumulative effective dose (CED) from all thoracic and extrathoracic imaging modalities and interventional radiology procedures for both adult and pediatric patients with CF, exclusively attending a nationally designated CF center between 1992-2009 for > 1 year, was determined. The study period was divided into three equal tertiles, and estimated CED attributable to all radiologic procedures was estimated for each tertile.

RESULTS

Two hundred thirty patients met inclusion criteria (2,240 person-years of follow-up; 5,596 radiologic procedures). CED was > 75 mSv for one patient (0.43%), 36 patients (15.6%) had a CED between 20 and 75 mSv, 56 patients (24.3%) had a CED between 5 and 20 mSv, and in 138 patients (60%) the CED was estimated to be between 0 and 5 mSv over the study period. The mean annual CED per patient increased consecutively from 0.39 mSv/y to 0.47 mSv/y to 1.67 mSv/y over the tertiles one to three of the study period, respectively (P < .001). Thoracic imaging accounted for 46.9% of the total CED and abdominopelvic imaging accounted for 42.9% of the CED, respectively. There was an associated 5.9-fold increase in the use of all CT scanning per patient (P < .001).

CONCLUSIONS

This study highlights the increasing exposure to ionizing radiation to patients with CF as a result of diagnostic imaging, primarily attributable to CT scanning. Increased awareness of CED and strategies to reduce this exposure are needed.

Для цитирования: O'Connell Oisin J, McWilliams Sebastian, McGarrigle AnneMarie, O'Connor Owen J, Shanahan Fergus, Mullane David, Eustace Joseph, Maher Michael M, Plant Barry J. Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades.. Chest. 2011. DOI: 10.1378/chest.11-1972.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.