m+Medelevator.RU
← Поиск публикаций
NMR in biomedicine · 2026

MRI Goes Mobile: Assessing the Reliability and Repeatability of a Mobile vs. Stationary 1.5 T MRI for Functional Neuroscience Studies.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Aigner Christoph Stefan, Forlim Caroline Garcia, Santoro Davide, Bodammer Nils C, Brühl Rüdiger, Sudimac Sonja, Schmalen Katharina, Schröder Sebastian, Mohammadi Siawoosh, Kühn Simone

Аннотация

Mobile MRI scanners could transform neuroimaging by expanding accessibility to diverse populations and enabling data collection in remote settings. This study serves as a short-term feasibility and system commissioning report, investigating the reliability and repeatability of two mobile 1.5 T MRI scanners compared to a stationary 1.5 T reference. To evaluate the technical impact of scanner relocation and mobile housing, a comprehensive protocol was implemented: five healthy subjects underwent 10 scans each (N = 50 total sessions) across three 1.5 T systems (one stationary; two mobile). The protocol employed a test-retest design with participant repositioning on each measurement day. Stability was assessed through longitudinal fBIRN phantom scans and human imaging of magnetic field homogeneity (ΔB0), RF flip-angle mapping (B1 +), structural MP-RAGE, and functional EPI-BOLD. Initial commissioning results demonstrated that short-term relocation and mobile operation did not compromise hardware performance. Phantom QA showed stable tSNR and minimal signal drift. In human subjects, magnetic field stability (ΔB0) and B1 + distributions were equivalent across systems, with Bland-Altman plots confirming no systematic bias following transit. Structural MP-RAGE voxel-intensity distributions and tissue volumes were highly consistent, with ICCs between 0.99 and 1 for estimated WM and GM volumes. This technical validation study demonstrates the short-term feasibility of utilizing mobile 1.5 T platforms for high-quality neuroimaging. The results confirm that current mobile shielding and stabilization technologies effectively mitigate the environmental challenges of transit, establishing a reliable baseline for future longitudinal research in remote or underserved settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты