MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ebiom.2024.105164

Медицинская библиотека · EBioMedicine · 2024

Towards a machine-learning assisted non-invasive classification of dengue severity using wearable PPG data: a prospective clinical study.

Karolcik Stefan, Manginas Vasileos, Chanh Ho Quang, Daniels John, Giang Nguyen Thi, Huyen Vu Ngo Thanh, Hoang Minh Tu Van, Phan Nguyen Quoc Khanh, Hernandez Bernard, Ming Damien K, Nguyen Van Hao, Phan Tu Qui, Trieu Huynh Trung, Luong Thi Hue Tai, Holmes Alison H, Thwaites Louise, Phan Vinh Tho, Yacoub Sophie, Georgiou Pantelis, Vietnam ICU Translational Applications Laboratory (VITAL) Investigators

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Dengue epidemics impose considerable strain on healthcare resources. Real-time continuous and non-invasive monitoring of patients admitted to the hospital could lead to improved care and outcomes. We evaluated the performance of a commercially available wearable (SmartCare) utilising photoplethysmography (PPG) to stratify clinical risk for a cohort of hospitalised patients with dengue in Vietnam.

METHODS

We performed a prospective observational study for adult and paediatric patients with a clinical diagnosis of dengue at the Hospital for Tropical Disease, Ho Chi Minh City, Vietnam. Patients underwent PPG monitoring early during admission alongside standard clinical care. PPG waveforms were analysed using machine learning models. Adult patients were classified between 3 severity classes: i) uncomplicated (ward-based), ii) moderate-severe (emergency department-based), and iii) severe (ICU-based). Data from paediatric patients were split into 2 classes: i) severe (during ICU stay) and ii) follow-up (14-21 days after the illness onset). Model performances were evaluated using standard classification metrics and 5-fold stratified cross-validation.

FINDINGS: We included PPG and clinical data from 132 adults and 15 paediatric patients with a median age of 28 (IQR, 21-35) and 12 (IQR, 9-13) years respectively. 1781 h of PPG data were available for analysis. The best performing convolutional neural network models (CNN) achieved a precision of 0.785 and recall of 0.771 in classifying adult patients according to severity class and a precision of 0.891 and recall of 0.891 in classifying between disease and post-disease state in paediatric patients.

INTERPRETATION: We demonstrate that the use of a low-cost wearable provided clinically actionable data to differentiate between patients with dengue of varying severity. Continuous monitoring and connectivity to early warning systems could significantly benefit clinical care in dengue, particularly within an endemic setting. Work is currently underway to implement these models for dynamic risk predictions and assist in individualised patient care.

FUNDING: EPSRC Centre for Doctoral Training in High-Performance Embedded and Distributed Systems (HiPEDS) (Grant: EP/L016796/1) and the Wellcome Trust (Grants: 215010/Z/18/Z and 215688/Z/19/Z).

Для цитирования: Karolcik Stefan, Manginas Vasileos, Chanh Ho Quang, Daniels John, Giang Nguyen Thi, Huyen Vu Ngo Thanh, Hoang Minh Tu Van, Phan Nguyen Quoc Khanh, Hernandez Bernard, Ming Damien K, Nguyen Van Hao, Phan Tu Qui, Trieu Huynh Trung, Luong Thi Hue Tai, Holmes Alison H, Thwaites Louise, Phan Vinh Tho, Yacoub Sophie, Georgiou Pantelis, Vietnam ICU Translational Applications Laboratory (VITAL) Investigators. Towards a machine-learning assisted non-invasive classification of dengue severity using wearable PPG data: a prospective clinical study.. EBioMedicine. 2024. DOI: 10.1016/j.ebiom.2024.105164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.