m+Medelevator.RU
← Поиск публикаций
American journal of ophthalmology · 2015

Full-Thickness Macular Hole Secondary to High-Power Handheld Blue Laser: Natural History and Management Outcomes.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Alsulaiman Sulaiman M, Alrushood Abdulaziz Adel, Almasaud Jluwi, Alkharashi Abdullah S, Alzahrani Yahya, Abboud Emad B, Nowilaty Sawsan R, Arevalo J Fernando, Al-Amry Mohammad, Alrashaed Saba, Ghazi Nicola G, King Khaled Eye Specialist Hospital Collaborative Retina Study Group

Аннотация

PURPOSE: To report the natural history and management outcomes of full-thickness macular hole (MH) caused by momentary exposure to a high-power handheld blue laser device and highlight the dangers of such easily available devices.

DESIGN: Retrospective consecutive case series.

METHODS: A chart review of all patients presenting with full-thickness MH from exposure to blue-light high-powered lasers from January 2012 to May 2014 at 2 institutions was performed. Evaluation included a full ophthalmic examination, fundus photography, macular spectral-domain optical coherence tomography, and fundus fluorescein angiography. The main and secondary outcomes were MH closure and final visual acuity, respectively.

RESULTS: There were 17 eyes of 17 patients with full-thickness MH. Best-corrected Snellen visual acuity (BCVA) at presentation ranged from 20/30 to 2/200 (mean: 20/210). The MH minimum diameter ranged from 168 μm to 620 μm (mean: 351 μm). Fourteen eyes underwent pars plana vitrectomy, internal limiting membrane peeling, and gas or silicone oil tamponade. Eleven of the 14 (78.6%) operated eyes had complete closure of the macular hole. Of the 3 unoperated eyes, only 1 eye with the smallest macular hole (minimum diameter: 168 μm) closed spontaneously with observation. Final BCVA in all cases had a mean of 20/62 (range: 20/20-4/200).

CONCLUSION: Full-thickness MH can result from momentary exposure to high-power handheld laser devices. While spontaneous closure may occur in rare cases, most cases require early surgical intervention. Vitrectomy may be successful in closing the macular hole with visual acuity improvement in most of the cases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты