MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.24892

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2013

The use of vascular closure devices and impact on major bleeding and net adverse clinical events (NACEs) in balloon aortic valvuloplasty: a sub-analysis of the BRAVO study.

O'Neill Brian, Singh Vikas, Kini Annapoorna, Mehran Roxana, Jacobs Evan, Knopf David, Alfonso Carlos E, Martinez Claudia A, Martinezclark Pedro, O'Neill William, Heldman Alan W, Yu Jennifer, Baber Usman, Kovacic Jason C, Dangas George, Sharma Samin, Sartori Samantha, Cohen Mauricio G

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To determine the impact of suture-mediated vascular closure devices (VCDs) on net adverse clinical events (NACEs) after balloon aortic valvuloplasty (BAV).

BACKGROUND

Ischemic and bleeding complications are common following transfemoral BAV; however, previous studies have been single center and limited by varying definitions of major bleeding.

METHODS

The Effect of Bivalirudin on Aortic Valve Intervention Outcomes (BRAVOs) study was a retrospective observational study conducted at two high-volume academic centers over a 6-year period designed to compare the effect of bivalirudin versus unfractionated heparin. This is a subanalysis of 428 consecutive patients who underwent BAV (with 10-13 French sheaths) to compare the effect of hemostasis with VCDs versus manual compression utilizing standardized definitions. NACE was defined as the composite of major bleeding and major adverse clinical events (MACEs). All events were adjudicated by an independent clinical events committee who were blinded to antithrombin use.

RESULTS

Preclosure was performed in 269 (62.8%) of patients. While bivalirudin was used more frequently in those with pre-closure (60.6% vs. 37.7%, P < 0.001), a history of prior BAV (11.1% vs. 3.6%, P = 0.04) and peripheral vascular disease (30.7% vs. 19.7%, P = 0.01) was more common in those not undergoing preclosure (n = 159, 37%). Other clinical and demographic features were well balanced between groups. Vascular closure was associated with a significant reduction in NACE (24.5% vs. 10.0% P < 0.001). Results remained significant after adjusting for baseline differences and bivalirudin use (OR 0.38, 95% CI: 0.21-0.68; P = 0.001).

CONCLUSIONS

Our study suggests that suture-mediated vascular closure is associated with a substantial reduction in NACE after transfemoral BAV. Large randomized clinical trials should be conducted to confirm our results.

Для цитирования: O'Neill Brian, Singh Vikas, Kini Annapoorna, Mehran Roxana, Jacobs Evan, Knopf David, Alfonso Carlos E, Martinez Claudia A, Martinezclark Pedro, O'Neill William, Heldman Alan W, Yu Jennifer, Baber Usman, Kovacic Jason C, Dangas George, Sharma Samin, Sartori Samantha, Cohen Mauricio G. The use of vascular closure devices and impact on major bleeding and net adverse clinical events (NACEs) in balloon aortic valvuloplasty: a sub-analysis of the BRAVO study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2013. DOI: 10.1002/ccd.24892.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.