Cherenkov-excited fluorescence imaging for small-field dosimetry and SRS plan verification: a feasibility study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Enkavi Mehmet Fazil, Uysal Hasan, Oysul Kaan, Sirin Sait, Ersan Hulya Yavuz

Аннотация

Objective.To develop a high-spatial-resolution Cherenkov-excited fluorescence dosimetry system (CEFD) with rapid optical readout using quinine sulfate solution and evaluate its feasibility for small-field dosimetry and verification of patient-derived stereotactic radiosurgery (SRS) dose distributions.Approach.A 3D-printed optical phantom containing 1 g l-1quinine sulfate solution was imaged with a complementary metal-oxide-semiconductor camera through a 45° mirror. Sensitive-volume thicknesses of 2.5, 5, 10 and 15 mm were compared using calibration response, signal-to-noise ratio, output factors, dose-rate dependence, and small-field beam profiles benchmarked against a PTW 60023 microSilicon detector. The selected CEFD configuration was further evaluated for thermal response, repeatability, signal drift, low-MU response, and small-field gamma performance, and then used for fixed-gantry verification of 31 patient-derived SRS dose distributions. GafChromic EBT3 film was used as the high-spatial-resolution comparator.Main results.The CEFD achieved 0.065 mm pixel-1spatial sampling. CEFD-10 showed the most balanced overall performance across sensitivity, dose-rate response, output-factor agreement, and small-field profile measurements. Dose-rate deviations remained within 1.7% at 300-1400 MU min-1. Passive heat sinking reduced the coefficient of variation from 0.26%-0.13% and limited signal drift from 4.3%-0.97% over 30 consecutive measurements. For the 0.5 × 0.5 cm2field, the CEFD-10 central-axis dose ratio relative to the treatment planning system-projected dose remained within ±2% from 10 MU onward. For 0.5 × 0.5-3 × 3 cm2static fields, CEFD-10 achieved 99.56%-100.0% global 2%/1 mm gamma passing rates with a 10% low-dose threshold. For patient-derived SRS verification, CEFD-10 achieved mean global gamma passing rates of 99.47 ± 1.58% and 97.53 ± 3.58% for 2%/2 mm and 2%/1 mm criteria, respectively, with mean differences from EBT3 film of -0.32% and -0.21%, respectively.Significance.This study demonstrates compact, high-spatial-resolution, rapid-readout optical dosimetry for small-field and patient-derived SRS dose patterns. Agreement with EBT3 film supports CEFD-10 as a controlled-geometry SRS dose verification.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты