DOI 10.1186/s12886-026-05014-1
Operationalizing a minimal-metric school screening pathway: using non-cycloplegic spherical equivalent as a first-stage triage metric for hyperopia-reserve insufficiency in Chinese schoolchildren.
Аннотация
BACKGROUND
School-based myopia screening commonly relies on non-cycloplegic refraction because cycloplegic refraction is difficult to implement universally at scale. This study evaluated whether non-cycloplegic spherical equivalent (NC-SE) could serve as a low-burden first-stage triage metric to identify children who warrant cycloplegic assessment for possible hyperopia reserve insufficiency (HRI).
METHODS
This cross-sectional school-based study included 1,650 children aged 6-15 years from Zengcheng District, Guangzhou, China. All participants underwent non-cycloplegic autorefraction, UCVA assessment, and cycloplegic autorefraction. Cycloplegic spherical equivalent (Cyclo-SE) was used as the reference standard for defining HRI, cycloplegic myopia, and pseudomyopia. HRI was operationally defined as preserved UCVA with low cycloplegic hyperopic reserve: Cyclo-SE from 0 to + 1.25 D in children aged 6-8 years and from 0 to + 1.00 D in children aged 9-15 years. Diagnostic performance of NC-SE for identifying HRI was assessed using receiver operating characteristic (ROC) analysis.
RESULTS
The prevalence of HRI was 14.1%, 10.5%, and 3.9% in the 6-8, 9-11, and 12-15-year-old groups, respectively. Correlation between NC-SE and Cyclo-SE strengthened with age (Spearman's rho: 0.641, 0.675, and 0.813; all p < 0.001). For detecting HRI, NC-SE achieved an AUC of 0.661 (95% CI: 0.618-0.704). A pragmatic cutoff of -0.50 D yielded a sensitivity of 0.824 (95% CI: 0.765-0.870), specificity of 0.550 (95% CI: 0.524-0.575), PPV of 20.5% (95% CI: 17.9-23.4), and NPV of 95.7% (95% CI: 94.1-96.9). Among children with normal visual acuity, 24.1% had pseudomyopia.
CONCLUSION
NC-SE may serve as a low-burden first-stage triage metric in school-based screening to identify children who warrant cycloplegic assessment for possible HRI. However, its moderate AUC and low PPV indicate that NC-SE should not be interpreted as a stand-alone diagnostic test. Cycloplegic refraction remains necessary for confirming hyperopic reserve status. Further longitudinal studies incorporating axial length, accommodative measurements, and external validation are needed to determine its prognostic value for incident myopia.
CLINICAL TRIAL NUMBER: Not applicable.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.