Comparative Evaluation of High- versus Low-Viscosity Silicone Oil in Macula-Off Retinal Detachment: Emulsification, Inflammation, and AI-Assisted Biomarker Detection.

Mariotti Cesare, Iorio Silvia, Gregori Giulia, Nacciarriti Enrico, Mangoni Lorenzo, Rizzo Clara, Lupidi Marco

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The aim of this study was to compare the emulsification rates, intraocular pressure (IOP) changes, and retinal hyperreflective foci (HRF) between low-viscosity (1,000 cS) and high-viscosity (5,000 cS) silicone oils (SOs) used as tamponade agents following 25-gauge pars plana vitrectomy (PPV) in cases of naïve macula-off rhegmatogenous retinal detachment using an artificial intelligence (AI)-based quantification approach.

METHODS

This retrospective study was conducted in eyes treated with PPV and SO tamponade. The clinical parameters that were assessed included best-corrected visual acuity (BCVA), IOP, the presence of emulsification in the iridocorneal angle - in the anterior or posterior chambers, and structural retinal biomarkers such as intraretinal fluid, subretinal fluid, and HRF detected and quantified through an AI-based analysis of spectral-domain optical coherence tomography (OCT) images.

RESULTS

Twenty-five eyes were enrolled (12 with 1,000-cS SO and 13 with 5,000-cS SO endotamponades) for this study. No statistically significant differences in BCVA or anatomical outcomes between the two groups were found. However, SO emulsification occurred more often in the 1,000-cS group (66%) compared to the 5,000-cS group (7%) (p = 0.0036). Elevated IOP was more frequent in the 1,000-cS group (8 vs. 4 cases; p = 0.03), and HRF count was significantly higher in eyes with 1,000-cS oil (p = 0.04).

CONCLUSION

High-viscosity SO demonstrated a lower emulsification rate and reduced inflammatory response compared to low-viscosity SO, with no compromise in visual outcomes. AI-assisted OCT analysis enabled an accurate, automated detection of HRF, supporting its utility in monitoring SO-related complications.

Для цитирования: Mariotti Cesare, Iorio Silvia, Gregori Giulia, Nacciarriti Enrico, Mangoni Lorenzo, Rizzo Clara, Lupidi Marco. Comparative Evaluation of High- versus Low-Viscosity Silicone Oil in Macula-Off Retinal Detachment: Emulsification, Inflammation, and AI-Assisted Biomarker Detection.. Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde. 2026. DOI: 10.1159/000551074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.