MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7754/clin.lab.2020.200746

Медицинская библиотека · Clinical laboratory · 2021

Evaluation of Aspergillus Lateral-Flow Test in Serum Samples of Pediatric Patients.

Felek Rasih, Erman-Daloglu Aylin, Ozhak Betil, Ogunc Dilara, Ongut Gozde, Gunseren Filiz, Kupesiz Alphan, Colak Dilek

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Diagnosis of invasive aspergillosis (IA) in patients with hematologic malignancies and under the risk of IA may be uncertain or may delay because of nonspecific clinical presentation of the patients and difficult application techniques of conventional methods. Early diagnosis can provide initial antifungal therapy and prevent high mortality. In this study, we investigated the performance of an Aspergillus lateral-flow device (LFD) test (OLM Diagnostics, Newcastle upon Tyne, United Kingdom) for the diagnosis of IA in pediatric febrile neutropenic patients with hematologic malignancies.

METHODS

Three hundred and fourty seven serum samples of 26 febrile neutropenic episodes of 21 patients at risk for IA were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the Aspergillus LFD test at episode level and at serum level were calculated.

RESULTS

According to the reference diagnostic criteria of IA, one proven and 13 probable IA episodes were defined. Twelve episodes (46.1%) did not meet the criteria for IA. The sensitivity, specificity, PPV, NPV, accuracy of the Aspergillus LFD test at episode level and at serum level were 14.3%, 100%, 100%, 50%, 53.8% and 12.1%, 100%, 100%, 50.8%, 53.9%, respectively.

CONCLUSIONS

Aspergillus LFD test is an easy-to-use assay with short hands-on time; however, further study of the clinical utility in children and especially in serum samples are needed. It is a highly specific test for IA on bronchoalveolar lavage (BAL) samples but is not useful as a screening test for serum samples unless combined with galactomannan (GM) antigen test because of its potentially suboptimal sensitivity.

Для цитирования: Felek Rasih, Erman-Daloglu Aylin, Ozhak Betil, Ogunc Dilara, Ongut Gozde, Gunseren Filiz, Kupesiz Alphan, Colak Dilek. Evaluation of Aspergillus Lateral-Flow Test in Serum Samples of Pediatric Patients.. Clinical laboratory. 2021. DOI: 10.7754/clin.lab.2020.200746.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.