Iseri M, Ustundag E, Ulubil A, Ozturk M, Bircan O
Аннотация
OBJECTIVE: To analyse patients with cholesteatoma undergoing canal wall down mastoidectomy together with ossicular reconstruction with a titanium prosthesis, in order to identify factors associated with hearing outcomes.
STUDY DESIGN: Retrospective review of 97 cases undergoing single-stage surgical management.
METHODS: All patients underwent canal wall down mastoidectomy. Kurz titanium ossicular prostheses were used for ossicular chain reconstruction. Pre-operative and post-operative air conduction and bone conduction hearing thresholds were obtained at 500, 1000, 2000 and 3000 Hz.
RESULTS: The mean pure tone average improved from 46.02 ± 14.54 dB pre-operatively to 29.32 ± 14.64 dB post-operatively, for both total and partial ossicular replacement prosthesis groups combined. The mean air-bone gap improved from 30.38 ± 11.12 dB pre-operatively to 15.62 ± 9.65 dB post-operatively, for both groups combined.
CONCLUSION: Reconstruction with a titanium prosthesis offers good functional results when performed during canal wall down surgery for advanced cholesteatoma, as a single-stage procedure.
STUDY DESIGN: Retrospective review of 97 cases undergoing single-stage surgical management.
METHODS: All patients underwent canal wall down mastoidectomy. Kurz titanium ossicular prostheses were used for ossicular chain reconstruction. Pre-operative and post-operative air conduction and bone conduction hearing thresholds were obtained at 500, 1000, 2000 and 3000 Hz.
RESULTS: The mean pure tone average improved from 46.02 ± 14.54 dB pre-operatively to 29.32 ± 14.64 dB post-operatively, for both total and partial ossicular replacement prosthesis groups combined. The mean air-bone gap improved from 30.38 ± 11.12 dB pre-operatively to 15.62 ± 9.65 dB post-operatively, for both groups combined.
CONCLUSION: Reconstruction with a titanium prosthesis offers good functional results when performed during canal wall down surgery for advanced cholesteatoma, as a single-stage procedure.