Jin Chao, Zhao Huifang, Li Huan, Chen Peiyao, Tian Cong, Li Xianjun, Wang Miaomiao, Liu Congcong, Sun Qinli, Zheng Jie, Li Baiya, Zhou Xihui, Salvi Richard, Yang Jian
Аннотация
BACKGROUND: Neonates with immature auditory function (eg, weak/absent middle ear muscle reflex) could conceivably be vulnerable to noise-induced hearing loss; however, it is unclear if neonates show evidence of hearing loss following MRI acoustic noise exposure.
PURPOSE: To explore the auditory effects of MRI acoustic noise in neonates.
STUDY TYPE: Prospective.
SUBJECTS: Two independent cohorts of neonates (N = 19 and N = 18; mean gestational-age, 38.75 ± 2.18 and 39.01 ± 1.83 weeks).
FIELD STRENGTH/SEQUENCE: T1-weighted three-dimensional gradient-echo sequence, T2-weighted fast spin-echo sequence, single-shot echo-planar imaging-based diffusion-tensor imaging, single-shot echo-planar imaging-based diffusion-kurtosis imaging and T2-weighted fluid-attenuated inversion recovery sequence at 3.0 T.
ASSESSMENT: All neonates wore ear protection during scan protocols lasted ~40 minutes. Equivalent sound pressure levels (SPLs) were measured for both cohorts. In cohort1, left- and right-ear auditory brainstem response (ABR) was measured before (baseline) and after (follow-up) MRI, included assessment of ABR threshold, wave I, III and V latencies and interpeak interval to determine the functional status of auditory nerve and brainstem. In cohort2, baseline and follow-up left- and right-ear distortion product otoacoustic emission (DPOAE) amplitudes were assessed at 1.2 to 7.0 kHz to determine cochlear function.
STATISTICAL TEST: Wilcoxon signed-rank or paired t-tests with Bonferroni's correction were used to compare the differences between baseline and follow-up ABR and DPOAE measures.
RESULTS: Equivalent SPLs ranged from 103.5 to 113.6 dBA. No significant differences between baseline and follow-up were detected in left- or right-ear ABR measures (P > 0.999, Bonferroni corrected) in cohort1, or in DPOAE levels at 1.2 to 7.0 kHz in cohort2 (all P > 0.999 Bonferroni corrected except for left-ear levels at 3.5 and 7.0 kHz with corrected P = 0.138 and P = 0.533).
DATA CONCLUSION: A single 40-minute 3-T MRI with equivalent SPLs of 103.5-113.6 dBA did not result in significant transient disruption of auditory function, as measured by ABR and DPOAE, in neonates with adequate hearing protection.
EVIDENCE LEVEL: 2.
TECHNICAL EFFICACY: Stage 5.
PURPOSE: To explore the auditory effects of MRI acoustic noise in neonates.
STUDY TYPE: Prospective.
SUBJECTS: Two independent cohorts of neonates (N = 19 and N = 18; mean gestational-age, 38.75 ± 2.18 and 39.01 ± 1.83 weeks).
FIELD STRENGTH/SEQUENCE: T1-weighted three-dimensional gradient-echo sequence, T2-weighted fast spin-echo sequence, single-shot echo-planar imaging-based diffusion-tensor imaging, single-shot echo-planar imaging-based diffusion-kurtosis imaging and T2-weighted fluid-attenuated inversion recovery sequence at 3.0 T.
ASSESSMENT: All neonates wore ear protection during scan protocols lasted ~40 minutes. Equivalent sound pressure levels (SPLs) were measured for both cohorts. In cohort1, left- and right-ear auditory brainstem response (ABR) was measured before (baseline) and after (follow-up) MRI, included assessment of ABR threshold, wave I, III and V latencies and interpeak interval to determine the functional status of auditory nerve and brainstem. In cohort2, baseline and follow-up left- and right-ear distortion product otoacoustic emission (DPOAE) amplitudes were assessed at 1.2 to 7.0 kHz to determine cochlear function.
STATISTICAL TEST: Wilcoxon signed-rank or paired t-tests with Bonferroni's correction were used to compare the differences between baseline and follow-up ABR and DPOAE measures.
RESULTS: Equivalent SPLs ranged from 103.5 to 113.6 dBA. No significant differences between baseline and follow-up were detected in left- or right-ear ABR measures (P > 0.999, Bonferroni corrected) in cohort1, or in DPOAE levels at 1.2 to 7.0 kHz in cohort2 (all P > 0.999 Bonferroni corrected except for left-ear levels at 3.5 and 7.0 kHz with corrected P = 0.138 and P = 0.533).
DATA CONCLUSION: A single 40-minute 3-T MRI with equivalent SPLs of 103.5-113.6 dBA did not result in significant transient disruption of auditory function, as measured by ABR and DPOAE, in neonates with adequate hearing protection.
EVIDENCE LEVEL: 2.
TECHNICAL EFFICACY: Stage 5.