MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/s0004-27492012000600009

Медицинская библиотека · Arquivos brasileiros de oftalmologia · 2012

Macular hole: 10 and 20-MHz ultrasound and spectral-domain optical coherence tomography.

Bottós Juliana Mantovani, Torres Virginia Laura Lucas, Kanecadan Liliane Andrade Almeida, Martinez Andrea Alejandra Gonzalez, Moraes Nilva Simeren Bueno, Maia Mauricio, Allemann Norma

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Optical coherence tomography (OCT) is valuable for macula evaluation. However, as this technique relies on light energy it cannot be performed in the presence of opaque media. In such cases, the ultrasound (US) may predict some macular features. The aim of this study was to characterize images obtained by ultrasound with 10 and 20-MHz transducers comparing to OCT, as well as to analyze the relationship between the vitreous and retina in eyes with macular hole (MH).

METHODS

29 eyes of 22 patients with biomicroscopic evidence of MH at different stages were included. All patients were evaluated using ultrasonography with 10 and 20-MHz transducers and OCT.

RESULTS

OCT identified signs of MH in 25 of 29 eyes. The remaining 4 cases not identified by US were pseudoholes caused by epiretinal membranes. In MH stages I (2 eyes) and II (1 eye), both transducers were not useful to analyze the macular thickening, but suggestive findings as macular irregularity, operculum or partial posterior vitreous detachment (PVD) were highlighted. In stages III (14 eyes) and IV (5 eyes), both transducers identified the double hump irregularity and thickening. US could measure the macular thickness and other suggestive findings for MH: operculum, vitreomacular traction and partial or complete PVD. In cases of pseudoholes, US identified irregularities macular contour and a discrete depression.

CONCLUSION

10-MHz US was useful for an overall assessment of the vitreous body as well as its relationship to the retina. The 20-MHz transducer allowed valuable information on the vitreomacular interface and macular contour. OCT provides superior quality for fine morphological study of macular area, except in cases of opaque media. In these cases, and even if OCT is not available, the combined US study is able to provide a valid evaluation of the macular area improving therapeutic approach.

Для цитирования: Bottós Juliana Mantovani, Torres Virginia Laura Lucas, Kanecadan Liliane Andrade Almeida, Martinez Andrea Alejandra Gonzalez, Moraes Nilva Simeren Bueno, Maia Mauricio, Allemann Norma. Macular hole: 10 and 20-MHz ultrasound and spectral-domain optical coherence tomography.. Arquivos brasileiros de oftalmologia. 2012. DOI: 10.1590/s0004-27492012000600009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.