Arquivos brasileiros de oftalmologia · 2013
[Biometry in the growth of the high myopic eye in childhood].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Franco Adriana Miranda de Magalhães, Lopes Yara Cristina, Souza Paulo Henrique de, Allemann Norma
Аннотация
PURPOSE: To determine if the growth of the axial length measured by optical and ultrasound biometry in a pediatric population of high myopes is significant, as well as significant variation of lens thickness, anterior chamber depth, corneal curvature and ophthalmoscopic findings during follow-up.
METHODS: A pediatric population (mean age: 8.7 years old) of 11 high myopic eyes (mean initial refractive error: -11.28 D) was submitted to serial evaluation over a 9-months period including optical (IOLMaster, Zeiss) and ultrasound biometry (Ultrascan, Alcon, contact technique), cycloplegic refraction, indirect ophthalmoscopy and fundus photography.
RESULTS: During a 9-months period, eye growth was significant in 64% (7 eyes) and did not occur in 36% (3 eyes), with change in the mean axial length (pre=26.76 mm; final=26.98 mm). During this period, refractive spherical equivalent increased in 45% (5 eyes), did not show variation in 27% (3 eyes), with a change in mean refraction (pre=-11.28 D; final=-11.69 D). There was no statistically significant variation of lens thickness, anterior chamber depth, corneal curvature and ophthalmoscopic findings.
CONCLUSION: Ocular globe growth (axial length) measured by optic and ultrasound biometry was significant in the high myopic pediatric population examined. The findings suggest that axial length variation preceded variation of other structures in the sample examined. In a group of children with high myopia followed during a 9-months period, ocular growth was demonstrated with variation of axial length either with optical or ultrasound biometry techniques, and change in mean refraction. Other parameters studied as lens thickness, anterior chamber depth and corneal curvature did not demonstrate variation during the time of the study.
METHODS: A pediatric population (mean age: 8.7 years old) of 11 high myopic eyes (mean initial refractive error: -11.28 D) was submitted to serial evaluation over a 9-months period including optical (IOLMaster, Zeiss) and ultrasound biometry (Ultrascan, Alcon, contact technique), cycloplegic refraction, indirect ophthalmoscopy and fundus photography.
RESULTS: During a 9-months period, eye growth was significant in 64% (7 eyes) and did not occur in 36% (3 eyes), with change in the mean axial length (pre=26.76 mm; final=26.98 mm). During this period, refractive spherical equivalent increased in 45% (5 eyes), did not show variation in 27% (3 eyes), with a change in mean refraction (pre=-11.28 D; final=-11.69 D). There was no statistically significant variation of lens thickness, anterior chamber depth, corneal curvature and ophthalmoscopic findings.
CONCLUSION: Ocular globe growth (axial length) measured by optic and ultrasound biometry was significant in the high myopic pediatric population examined. The findings suggest that axial length variation preceded variation of other structures in the sample examined. In a group of children with high myopia followed during a 9-months period, ocular growth was demonstrated with variation of axial length either with optical or ultrasound biometry techniques, and change in mean refraction. Other parameters studied as lens thickness, anterior chamber depth and corneal curvature did not demonstrate variation during the time of the study.