OBJECTIVE

At present, ultrasonic aspiration is routinely used in several fields of surgery, especially in brain and spinal micro-surgery for tumour removal. In order to broaden the access to difficult surgical sites, it is important to design highly miniaturised but still efficient handpieces. The internal resonant system, always made of high-grade materials, must be optimally dimensioned. Normally this is done semi-empirically, by successively improving the design during many iterative test steps. This method however involves several additional difficulties when the degree of miniaturisation increases. For example, small transducer weights exacerbate heat-dissipation problems and make design optimisation important.

METHODS

To resolve these problems we have produced modelling software that makes it possible to simulate and automatically tune each individual interacting section of the design before it is actually manufactured, thereby assuring optimal efficiency.

RESULTS

Using a new mini-handpiece, designed via the software, two cases of dissection of acoustic neurinomas were successfully performed.

CONCLUSION

Using conventional physical steps for improving ultrasonic aspiration handpieces, several problems arise when the grade of miniaturisation increases, due to increasing demands. We have designed computer software for handpiece simulation. Using this model it has been possible to manufacture a highly efficient miniaturised handpiece.

Для цитирования: Wiksell H, Martin H, Coakham H, Berggren A, Westermark S. Miniaturised ultrasonic aspiration handpiece for increased applicability.. European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology. 2000. DOI: 10.1016/s0929-8266(99)00069-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.