MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2500/aap.2020.41.200061

Медицинская библиотека · Allergy and asthma proceedings · 2020

Component resolved diagnostics in peanut sensitized children with and without a history of clinical reaction.

Hamzavi Abedi Yasmin, Sison Cristina P, Ponda Punita

СтатьяПеревод пока не подготовлен

Аннотация

Background

Serum Peanut-specific-IgE (PN-sIgE) and peanut-component-resolved-diagnostics (CRD) are often ordered simultaneously in the evaluation for peanut allergy. Results often guide the plans for peanut oral challenge. However, the clinical utility of CRD at different total PN-sIgE levels is unclear. A commonly used predefined CRD Ara h2 cutoff value in the literature predicting probability of peanut challenge outcomes is 0.35kUA/L.

Objective

To examine the utility of CRD in patients with and without a history of clinical reactivity to peanut (PN).

Methods

This was a retrospective chart review of 196 children with PN-sIgE and CRD testing, of which, 98 patients had a clinical history of an IgE-mediated reaction when exposed to PN and 98 did not. The Fisher's exact test was used to assess the relationship between CRD and PN-sIgE at different cutoff levels, McNemar test and Gwet's approach (AC1 statistic) were used to examine agreement between CRD and PN-sIgE, and logistic regression was used to assess differences in the findings between patients with and without reaction history.

Results

Ara h 1, 2, 3, or 9 (ARAH) levels ≤0.35 kUA/L were significantly associated with PN-sIgE levels <2 kUA/L rather than ≥2 kUA/L (p < 0.0001). When the ARAH threshold was increased to 1 kUA/L and 2 kUA/L, these thresholds were still significantly associated with PN-sIgE levels of <2, <5, and <14 kUA/L. These findings were not significantly different in patients with and without a history of clinical reactivity.

Conclusion

ARAH values correlated with PN-sIgE. Regardless of clinical history, ARAH levels are unlikely to be below 0.35, 1, or 2 kUA/L if the PN-sIgE level is >2 kUA/L. Thus, if possible, practitioners should consider PN-sIgE rather than automatically ordering CRD with PN-sIgE every time. Laboratory procedures that allow automatically and reflexively adding CRD when the PN-sIgE level is ≤5 kUA/L can be helpful. However, further studies are needed in subjects with challenge-proven PN allergy.

Для цитирования: Hamzavi Abedi Yasmin, Sison Cristina P, Ponda Punita. Component resolved diagnostics in peanut sensitized children with and without a history of clinical reaction.. Allergy and asthma proceedings. 2020. DOI: 10.2500/aap.2020.41.200061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.