MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jaapos.2012.10.014

Медицинская библиотека · Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2013

Clinical characteristics of patients that experience different rates of exodrift after strabismus surgery for intermittent exotropia and the effect of the rate of exodrift on final ocular alignment.

Park Ka Hee, Kim So Young

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the ocular motility factors associated with the rate of exodrift after surgical correction of intermittent exotropia and to determine whether the rate had an effect on the subsequent postoperative ocular alignment.

METHODS

Consecutive patients who underwent surgical correction of intermittent exotropia between 2009 and 2010 were observed for 12 months. Patients were divided into two groups, according to the averaged value of the rate of exodrift (fast vs slow). The ocular motility characteristics of the patients in each group were compared with identify factors that correlated with the speed of postoperative exodrift and to determine whether the rate had an effect on the final ocular alignment at 12 months after surgery.

RESULTS

A total of 159 patients underwent strabismus surgery during the study period. Of these, 130 experienced postoperative drift. The preoperative deviation at near and distance differed significantly between the fast and slow groups (P < 0.05) and was correlated to the rate of exodrift (near r = 0.427, distance r = 0.378): fast group, 32.09(Δ) ± 10.07(Δ), 27.60(Δ) ± 6.65(Δ); slow group, 31.74(Δ) ±10.34(Δ), 27.21(Δ) ± 6.03(Δ). The deviation at the first day after the surgery differed significantly between groups (P < 0.05) and was correlated to the rate of drift (r = 0.381): fast group, 4.72(Δ) ± 5.46(Δ) esotropia; slow group, 1.87(Δ) ± 4.40(Δ) esotropia. The two groups did not differ significantly in other factors. There were no differences in ocular alignment at 12 months' follow-up.

CONCLUSIONS

The rate of exodrift correlated with the size of the preoperative deviation and the amount of the initial postoperative overcorrection. It had no affect on the ocular alignment at 12 months after surgery.

Для цитирования: Park Ka Hee, Kim So Young. Clinical characteristics of patients that experience different rates of exodrift after strabismus surgery for intermittent exotropia and the effect of the rate of exodrift on final ocular alignment.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2013. DOI: 10.1016/j.jaapos.2012.10.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.