MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.10-6144

Медицинская библиотека · Investigative ophthalmology & visual science · 2011

Visual suppression in intermittent exotropia during binocular alignment.

Serrano-Pedraza Ignacio, Manjunath Vina, Osunkunle Olaoluwakitan, Clarke Michael P, Read Jenny C A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the cortical mechanisms that prevent diplopia in intermittent exotropia (X(T)) during binocular alignment (orthotropia).

METHODS

The authors studied 12 X(T) patients aged 5 to 22 years. Seventy-five percent had functional stereo vision with stereoacuity similar to that of 12 age-matched controls (0.2-3.7 min arc). Identical face images were presented to the two eyes for 400 ms. In one eye, the face was presented at the fovea; in the other, offset along the horizontal axis with up to 12° eccentricity. The task was to indicate whether one or two faces were perceived.

RESULTS

All X(T) patients showed normal diplopia when the nonfoveal face was presented to nasal hemiretina, though with a slightly larger fusional range than age-matched controls. However, 10 of 12 patients never experienced diplopia when the nonfoveal face was presented to temporal hemiretina (i.e., when the stimulus simulated exodeviation). Patients showed considerable variability when the single image was perceived. Some patients suppressed the temporal stimulus regardless of which eye viewed it, whereas others suppressed a particular eye even when it viewed the foveal stimulus. In two patients, the simulated exodeviation might have triggered a shift from normal to anomalous retinal correspondence.

CONCLUSIONS

Antidiplopic mechanisms in X(T) can be reliably triggered by purely retinal information during orthotropia, but the nature of these mechanisms varies between patients.

Для цитирования: Serrano-Pedraza Ignacio, Manjunath Vina, Osunkunle Olaoluwakitan, Clarke Michael P, Read Jenny C A. Visual suppression in intermittent exotropia during binocular alignment.. Investigative ophthalmology & visual science. 2011. DOI: 10.1167/iovs.10-6144.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.