m+Medelevator.RU
← Поиск публикаций
Journal of magnetic resonance imaging : JMRI · 2013

Inter-examination precision of magnitude-based MRI for estimation of segmental hepatic proton density fat fraction in obese subjects.

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Negrete Lindsey M, Middleton Michael S, Clark Lisa, Wolfson Tanya, Gamst Anthony C, Lam Jessica, Changchien Chris, Deyoung-Dominguez Ivan M, Hamilton Gavin, Loomba Rohit, Schwimmer Jeffrey, Sirlin Claude B

Аннотация

PURPOSE: To prospectively describe magnitude-based multi-echo gradient-echo hepatic proton density fat fraction (PDFF) inter-examination precision at 3 Tesla (T).

MATERIALS AND METHODS: In this prospective, Institutional Review Board-approved, Health Insurance Portability and Accountability Act (HIPAA) compliant study, written informed consent was obtained from 29 subjects (body mass indexes > 30 kg/m2). Three 3T MRI examinations were obtained over 75-90 min. Segmental, lobar, and whole liver PDFF were estimated (using three, four, five, or six echoes) by magnitude-based multi-echo MRI in colocalized regions of interest. For estimate (using three, four, five, or six echoes), at each anatomic level (segmental, lobar, whole liver), three inter-examination precision metrics were computed: intra-class correlation coefficient (ICC), standard deviation (SD), and range.

RESULTS: Magnitude-based PDFF estimates using each reconstruction method showed excellent inter-examination precision for each segment (ICC ≥ 0.992; SD ≤ 0.66%; range ≤ 1.24%), lobe (ICC ≥ 0.998; SD ≤ 0.34%; range ≤ 0.64%), and the whole liver (ICC = 0.999; SD ≤ 0.24%; range ≤ 0.45%). Inter-examination precision was unaffected by whether PDFF was estimated using three, four, five, or six echoes.

CONCLUSION: Magnitude-based PDFF estimation shows high inter-examination precision at segmental, lobar, and whole liver anatomic levels, supporting its use in clinical care or clinical trials. The results of this study suggest that longitudinal hepatic PDFF change greater than 1.6% is likely to represent signal rather than noise.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты