MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ppul.71424

Медицинская библиотека · Pediatric pulmonology · 2026

Impact of Palatal Expansion With Up-Locker on Children With Sleep-Disordered-Breathing: A Clinical Trial.

Restrepo Claudia, Kahn Sandra, Gozal David

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the effect of the palatal expansion with Hyrax and Hyrax + Up-Locker on sleep behavior, snoring and sleep architecture in children with Sleep Disordered Breathing (SDB).

MATERIALS AND

METHODS

This prospective, single-blind, randomized controlled clinical trial enrolled 34 children aged 6-8 years. Participants were randomly assigned using a computer-generated randomization process to receive treatment with either the Hyrax expansion appliance alone or in combination with the Up-Locker vacuum activator. Sleep architecture was evaluated via polysomnography and sleep behavior through the Children's Sleep Habits Questionnaire (CSHQ). Data were analyzed with Shapiro-Wilks for homogeneity and comparisons were performed with either t-test or Mann-Whitney.

RESULTS

Children in the Hyrax + Up-Locker exhibited superior outcomes than in the Hyrax group, including statistically significant reduction in sleep onset delay (p = 0.04) and night wakings (p = 0.02), as well as a notable decrease in snoring (p < 0.001). Children in the Hyrax + Up-Locker vacuum activator group experienced more significant improvements in sleep latency, total sleep time, REM sleep, AHI in REM and nREM sleep, and arousal indices compared to the Hyrax group (p < 0.05) after treatment.

CONCLUSION

Combined treatment with Hyrax + Up-Locker vacuum activator yielded superior outcomes in sleep architecture and sleep behavior.

TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06986343.

Для цитирования: Restrepo Claudia, Kahn Sandra, Gozal David. Impact of Palatal Expansion With Up-Locker on Children With Sleep-Disordered-Breathing: A Clinical Trial.. Pediatric pulmonology. 2026. DOI: 10.1002/ppul.71424.