MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2007.02.014

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2007

Buprenorphine assay and plasma concentration monitoring in HIV-infected substance users.

DiFrancesco Robin, Fischl Margaret A, Donnelly Julie, Zingman Barry S, McCance-Katz Elinore F, Moody David E, Reichman Richard C, Gripshover Barbara, Morse Gene D

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The availability of buprenorphine (BUP) provides an alternative approach to the treatment of opioid addiction with methadone, an agent that has many drug-drug interactions when combined with antiretroviral therapy (ART). However, due to limited long-term pharmacokinetic studies in HIV-infected patients, the clinical use of BUP, a CYP450-3A4 substrate, will require that studies be conducted to examine safety, tolerability and pharmacokinetics when these drugs are taken for chronic treatment. One clinical approach could include plasma concentration monitoring to avoid under- or overdosing BUP secondary to drug interactions with ART. The measurement of BUP and its active metabolite, norbuprenorphine (NBUP) facilitates the addition of BUP to ART in an attempt to avoid drug toxicity as described in a recent report by Bruce et al. Therefore, our objective was to validate a BUP assay and integrate its application into an ongoing antiretroviral (ARV) plasma concentration monitoring program. A chromatographic method for monitoring BUP and its active metabolite, NBUP was investigated. An assay was developed that would facilitate BUP and ARV measurement from a single 3 mL blood sample (0.75 mL plasma required) in conjunction with a previously validated multiple ARV HPLC method. The method measures BUP and NBUP over the range from 0.25 to 50 ng/mL with mass spectrometry detection. Inter- and intra-assay variation was <or=11%, across the concentration range. The method quantitates BUP and NBUP plasma concentrations within the range of expected values from current BUP dosing guidelines. Use of this combined BUP and ARV plasma concentration monitoring approach for a representative patient receiving BUP, atazanavir and efavirenz demonstrated its clinical application.

Для цитирования: DiFrancesco Robin, Fischl Margaret A, Donnelly Julie, Zingman Barry S, McCance-Katz Elinore F, Moody David E, Reichman Richard C, Gripshover Barbara, Morse Gene D. Buprenorphine assay and plasma concentration monitoring in HIV-infected substance users.. Journal of pharmaceutical and biomedical analysis. 2007. DOI: 10.1016/j.jpba.2007.02.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.