MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.08-2448

Медицинская библиотека · Investigative ophthalmology & visual science · 2009

Lipofuscin and autofluorescence metrics in progressive STGD.

Smith R Theodore, Gomes Nuno L, Barile Gaetano, Busuioc Mihai, Lee Noah, Laine Andrew

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate Stargardt disease (STGD) progression and relative lipofuscin levels via autofluorescence image analysis.

METHODS

The relationship between focally increased autofluorescence (FIAF), geographic atrophy (GA) and focally decreased autofluorescence (FDAF) was analyzed in serial, registered autofluorescence (AF) scans of 10 patients with STGD (20 eyes, 40 scans; mean follow-up, 2.0 years) using automated techniques.

RESULTS

GA progressed uniformly in a transition zone with minimal FIAF. Only 4.3% of FIAF progressed to GA or FDAF, despite significant progression of GA (median 30%/year) and FDAF (mean, 29%/year). As a spatial predictor, the mean chance of FIAF for progression to FDAF was 4.3% +/- 4.4%, significantly less than that of random areas (6.7% +/- 4.0%, P = 0.029, Mann-Whitney test). In the seven eyes with GA, the mean chance of FIAF in the transition zone for transition to GA was 12% +/- 8.9%, significantly less than that of random areas (33% +/- 3.6%, P = 0.026, Mann-Whitney test).

CONCLUSIONS

Autofluorescent flecks and FIAF deposits with AF levels elevated above the initial macular background were less likely in the short term (2 years) to transform to GA and FDAF (AF levels below the final background) than random areas, suggesting additional mechanisms beyond direct lipofuscin toxicity. FIAF/FDAF levels were observed to fluctuate, with focal remodeling of FIAF and FDAF, or rarely, even transition of FDAF to FIAF. FDAF tended to develop, not coincident with, but adjacent to initial FIAF. Because AF identifies these characteristic biological markers so specifically, autofluorescence metrics merit consideration in the study of STGD.

Для цитирования: Smith R Theodore, Gomes Nuno L, Barile Gaetano, Busuioc Mihai, Lee Noah, Laine Andrew. Lipofuscin and autofluorescence metrics in progressive STGD.. Investigative ophthalmology & visual science. 2009. DOI: 10.1167/iovs.08-2448.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.