Middle cerebral artery peak systolic velocity in fetuses with homozygous alpha-thalassemia-1: case series.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Raungrongmorakot Kasem, Chaemsaithong Piya
Аннотация
OBJECTIVES: The objective of this study is to evaluate the potential usefulness of middle cerebral artery peak systolic velocity (MCA-PSV) as a non-invasive means of detecting an anemic fetus from homozygous alpha-thalassemia-1.
MATERIAL AND METHOD: We observed four cases of referrals with complicated pregnancies in which the fetuses were suspected with homozygous alpha-thalassemia-1. Three out of four cases involved hydrop fetalis, detected through previous ultrasounds, while the remaining case was referred for prenatal diagnosis. Subsequently, we performed a detailed ultrasound and fetal MCA-PSV in all cases, and to confirm the diagnosis, we also performed cordocentesis.
RESULTS: With all the four cases having the gestational age range from 18 to 27 weeks, three showed hydrop fetalis. The remaining case, the 18-week gestational age fetus referred for prenatal diagnosis, showed an increase in the cardiothoracic ratio without other signs of hydrop fetalis. MCA-PSV suggested the presence of fetal anemia in all cases (with the velocity ranging from 37.3 to 62.2 cm/sec). The results obtained from cordocentesis confirmed fetal anemia and homozygous alpha-thalassemia-1 in all cases.
CONCLUSION: Peak systolic velocity of fetal middle cerebral artery can predict anemia in fetus affected with homozygous alpha-thalassemia-1 disease.
MATERIAL AND METHOD: We observed four cases of referrals with complicated pregnancies in which the fetuses were suspected with homozygous alpha-thalassemia-1. Three out of four cases involved hydrop fetalis, detected through previous ultrasounds, while the remaining case was referred for prenatal diagnosis. Subsequently, we performed a detailed ultrasound and fetal MCA-PSV in all cases, and to confirm the diagnosis, we also performed cordocentesis.
RESULTS: With all the four cases having the gestational age range from 18 to 27 weeks, three showed hydrop fetalis. The remaining case, the 18-week gestational age fetus referred for prenatal diagnosis, showed an increase in the cardiothoracic ratio without other signs of hydrop fetalis. MCA-PSV suggested the presence of fetal anemia in all cases (with the velocity ranging from 37.3 to 62.2 cm/sec). The results obtained from cordocentesis confirmed fetal anemia and homozygous alpha-thalassemia-1 in all cases.