Hydrus microstent compared to selective laser trabeculoplasty in primary open angle glaucoma: one year results.

Fea Antonio M, Ahmed Iqbal Ike K, Lavia Carlo, Mittica Pietro, Consolandi Giulia, Motolese Ilaria, Pignata Giulia, Motolese Eduardo, Rolle Teresa, Frezzotti Paolo

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

To compare the reduction of intraocular pressure (IOP) and glaucoma medications following selective laser trabeculoplasty (SLT) versus stand-alone placement of the Hydrus microstent, a microinvasive glaucoma surgery device.

DESIGN

Prospective interventional case-series. University practice.

PARTICIPANTS

Fifty six eyes (56 patients) with uncontrolled primary open-angle glaucoma.

METHODS

Patients received either SLT (n = 25) or Hydrus implantation (n = 31) in two centres. Patients were evaluated at baseline and 1, 7 days, 1, 3, 6 and 12 months after surgery.

MAIN OUTCOME MEASURES: Intraocular pressure and number of glaucoma medications variations inter-groups and intra-groups.

RESULTS

There were no significant differences at baseline between groups, but the mean deviation was worse in the Hydrus group (-8.43 ± 6.84 dB, confidence limits (CL)-2.8/-3.3 vs.-3.04 ± 0.65 dB, CL-6/-10.8; P < 0.001). After 12 months, there was a significant decrease in IOP and medications in the Hydrus group compared with baseline values. In the SLT group, only the decrease in IOP was significant. There was 3-fold greater reduction in medication use in the Hydrus group compared with SLT (-1.4 ± 0.97 vs.-0.5 ± 1.05, P = 0.001). 47% of patients were medication free at 12 months in the Hydrus group (4% in the SLT group). No complications were recorded in the SLT group. In the Hydrus group, three patients experienced a temporary reduction of visual acuity post-operatively, and two patients had post-operative IOP spikes that resolved within one week.

CONCLUSIONS

Both SLT and Hydrus implantation reduced IOP without serious adverse events. Hydrus implantation led to a significant and further reduction in medication dependence at 12 months.

Для цитирования: Fea Antonio M, Ahmed Iqbal Ike K, Lavia Carlo, Mittica Pietro, Consolandi Giulia, Motolese Ilaria, Pignata Giulia, Motolese Eduardo, Rolle Teresa, Frezzotti Paolo. Hydrus microstent compared to selective laser trabeculoplasty in primary open angle glaucoma: one year results.. Clinical & experimental ophthalmology. 2016. DOI: 10.1111/ceo.12805.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.