Magnetic resonance in medicine · 2019
SHORE-based detection and imputation of dropout in diffusion MRI.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Koch Alexandra, Zhukov Andrei, Stöcker Tony, Groeschel Samuel, Schultz Thomas
Аннотация
PURPOSE: In diffusion MRI, dropout refers to a strong attenuation of the measured signal that is caused by bulk motion during the diffusion encoding. When left uncorrected, dropout will be erroneously interpreted as high diffusivity in the affected direction. We present a method to automatically detect dropout, and to replace the affected measurements with imputed values.
METHODS: Signal dropout is detected by deriving an outlier score from a simple harmonic oscillator-based reconstruction and estimation (SHORE) fit of all measurements. The outlier score is defined to detect measurements that are substantially lower than predicted by SHORE in a relative sense, while being less sensitive to measurement noise in cases of weak baseline signal. A second SHORE fit is based on detected inliers only, and its predictions are used to replace outliers.
RESULTS: Our method is shown to reliably detect and accurately impute dropout in simulated data, and to achieve plausible results in corrupted in vivo dMRI measurements. Computational effort is much lower than with previously proposed alternatives.
CONCLUSIONS: Deriving a suitable outlier score from SHORE results in a fast and accurate method for detection and imputation of dropout in diffusion MRI. It requires measurements with multiple b values (such as multi-shell or DSI), but is independent from the models used for analysis (such as DKI, NODDI, deconvolution, etc.).
METHODS: Signal dropout is detected by deriving an outlier score from a simple harmonic oscillator-based reconstruction and estimation (SHORE) fit of all measurements. The outlier score is defined to detect measurements that are substantially lower than predicted by SHORE in a relative sense, while being less sensitive to measurement noise in cases of weak baseline signal. A second SHORE fit is based on detected inliers only, and its predictions are used to replace outliers.
RESULTS: Our method is shown to reliably detect and accurately impute dropout in simulated data, and to achieve plausible results in corrupted in vivo dMRI measurements. Computational effort is much lower than with previously proposed alternatives.
CONCLUSIONS: Deriving a suitable outlier score from SHORE results in a fast and accurate method for detection and imputation of dropout in diffusion MRI. It requires measurements with multiple b values (such as multi-shell or DSI), but is independent from the models used for analysis (such as DKI, NODDI, deconvolution, etc.).
Предметные рубрики MeSH
AdultAlgorithmsArtifactsBrainChildDiffusion Magnetic Resonance ImagingDiffusion Tensor ImagingHealthy VolunteersHumansImage EnhancementImage Interpretation, Computer-AssistedLeast-Squares AnalysisLeukodystrophy, MetachromaticMaleMonte Carlo MethodMotionOscillometryROC CurveReproducibility of ResultsSensitivity and Specificity