Calculations of S values and effective dose for the radioiodine carrier and surrounding individuals based on Chinese hybrid reference phantoms using the Monte Carlo technique.

Geng Changran, Tang Xiaobin, Qian Wei, Guan Fada, Johns Jesse, Yu Haiyan, Gong Chunhui, Shu Diyun, Chen Da

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The S values for the thyroid as the radioiodine source organ to other target organs were investigated using Chinese hybrid reference phantoms and the Monte Carlo code MCNP5. Two radioiodine isotopes (125)I and (131)I uniformly distributed in the thyroid were investigated separately. We compared our S values for (131)I in Chinese phantoms with previous studies using other types of phantoms: Oak Ridge National Laboratory (ORNL) stylized phantoms, International Commission on Radiological Protection (ICRP) voxel phantoms, and University of Florida (UF) phantoms. Our results are much closer to the UF phantoms. For each specific target organ, the S value for (131)I is larger than for (125)I in both male and female phantoms. In addition, the S values and effective dose to surrounding face-to-face exposed individuals, including different genders and ages (10- and 15-year-old juniors, and adults) from an adult male radioiodine carrier were also investigated. The target organ S values and effective dose for surrounding individuals obey the inverse square law with the distance between source and target phantoms. The obtained effective dose data in Chinese phantoms are comparable to the results in a previous study using the UF phantoms. The data generated in this study can serve as the reference to make recommendations for radiation protection of the Chinese patients or nuclear workers.

Для цитирования: Geng Changran, Tang Xiaobin, Qian Wei, Guan Fada, Johns Jesse, Yu Haiyan, Gong Chunhui, Shu Diyun, Chen Da. Calculations of S values and effective dose for the radioiodine carrier and surrounding individuals based on Chinese hybrid reference phantoms using the Monte Carlo technique.. Journal of radiological protection : official journal of the Society for Radiological Protection. 2015. DOI: 10.1088/0952-4746/35/3/707.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.