MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1645/20-57

Медицинская библиотека · The Journal of parasitology · 2021

Description and Molecular Differentiation of a New Falcaustra (Nematode: Kathlaniidae) from the Indochinese Water Dragon, Physignathus cocincinus (Squamata: Agamidae) in North-central Vietnam.

Van Ha Nguyen, An Ong Vinh, Sato Hiroshi, Greiman Stephen E, Linh Le Thi Mai, Binh Tran Thi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Although ophthalmic viscosurgical devices are quite important for safe cataract surgery, currently, postoperative residual ophthalmic viscosurgical devices can cause various complications. Previously, we developed a method to visualize residual ophthalmic viscosurgical devices after irrigation/aspiration in vitro and found that the amount of residual ophthalmic viscosurgical device on a single-piece intraocular lens was greater than that on a three-piece intraocular lens. In the present study, we compared the amounts of residual ophthalmic viscosurgical device among various foldable intraocular lenses to investigate the factors that determine the quantity of residual ophthalmic viscosurgical device.

PATIENTS AND

METHODS

Simulated cataract surgery was performed in pig eyes using an ophthalmic viscosurgical device labeled with fluorescent silica particles. After the simulated surgery procedure, the fluorescent silica attached to the intraocular lens was observed and quantified by inductively coupled plasma-atomic emission spectrometry after intraocular lens removal. The amount of residual ophthalmic viscosurgical device was compared among five representative single-piece intraocular lenses and one three-piece intraocular lens.

RESULTS

The distribution and amount of the residual ophthalmic viscosurgical device differed for each intraocular lens. The amount of silicon in the lens capsule differed among the intraocular lens types.

CONCLUSION

The postoperative residual tendency of ophthalmic viscosurgical devices differed among various single-piece intraocular lenses. The behavior of the intraocular lenses within the capsule affected the residual tendency. The removal of ophthalmic viscosurgical device in the lens capsule should be tailored for each intraocular lens to improve efficiency.

Для цитирования: Van Ha Nguyen, An Ong Vinh, Sato Hiroshi, Greiman Stephen E, Linh Le Thi Mai, Binh Tran Thi. Description and Molecular Differentiation of a New Falcaustra (Nematode: Kathlaniidae) from the Indochinese Water Dragon, Physignathus cocincinus (Squamata: Agamidae) in North-central Vietnam.. The Journal of parasitology. 2021. DOI: 10.1645/20-57.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.