MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/opo.13191

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2023

Multiple segment spectacle lenses for myopia control. Part 1: Optics.

Radhakrishnan Hema, Lam Carly Siu Yin, Charman W Neil

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To understand and compare the optics of two multiple segment (MS) spectacle lenses (Hoya MiyoSmart and Essilor Stellest) designed to inhibit myopia progression in children.

METHODS

The optics of the two designs are presented, together with geometrical optics-based calculations to understand the impact of the lenses on the optics of the eye. Lenses were evaluated with three techniques: surface images, Twyman-Green interferometry and focimetry. The carrier lens powers and the spatial distribution, powers and forms of the lenslets were measured.

RESULTS

MS lenses as manufactured were found to match most of the design specifications provided by their manufacturers, although some apparent small discrepancies were found. The focimeter-measured power of the lenslets was approximately +3.50 D for the MiyoSmart and +4.00 D for the highly aspheric lenslets of the Stellest design. For both lens designs, image contrast would be expected to become modestly reduced in the focal planes of the distance-correcting carrier lenses. Images become much more degraded in the combined carrier-lenslet focal plane, due to the generation of multiple laterally displaced images formed by adjacent lenslets within the effective pupil. The exact effects observed depended on the effective pupil size and its location with respect to the lenslets, as well as the power and arrangement of the lenslets.

CONCLUSION

Wearing either of these lenses will produce broadly similar effects on retinal imagery.

Для цитирования: Radhakrishnan Hema, Lam Carly Siu Yin, Charman W Neil. Multiple segment spectacle lenses for myopia control. Part 1: Optics.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2023. DOI: 10.1111/opo.13191.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.