MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajodo.2024.11.011

Медицинская библиотека · American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2025

Dentoskeletal effects of molar distalization with miniscrew-anchored cantilever and pendulum appliance for Class II correction.

Campos Cassio Bernard Alves, Vilanova Lorena, Alessio Junior Luiz Eduardo, Miranda Felicia, Garib Daniela, Henriques José Fernando Castanha

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

The objective of this study was to compare the dental and skeletal changes promoted by the miniscrew-anchored cantilever and pendulum appliance for Class II correction.

METHODS

This retrospective study involved 52 patients with Class II malocclusion divided into 2 groups according to the treatment received: the miniscrew group (MG) with 23 patients (14 females and 9 males; mean initial age of 12.42 years) treated using the miniscrew-anchored cantilever, and the pendulum group (PG) with 29 patients (21 females and 8 males; mean initial age of 13.60 years) treated using the pendulum appliance. Lateral cephalograms and digital dental models were obtained and analyzed in 2 phases: pretreatment and postdistalization. Intergroup comparisons were performed using t test, Mann-Whitney test, and multivariate analysis of covariance test for covariates (P <0.05).

RESULTS

Both groups exhibited similar molar distalization (3.25 ± 1.68 mm for MG and 2.90 ± 2.17 mm for PG). The MG showed distalization of premolars (2.03 ± 2.09 mm) and incisors (1.70 ± 2.27 mm), whereas the PG exhibited mesialization of premolars (3.24 ± 2.01 mm) and incisors (2.30 ± 2.60 mm). A greater distal rotation (20.20° ± 5.73° for MG and 4.26° ± 6.41° for PG; P <0.001) and smaller distal angulation (8.55° ± 3.75° for MG and 14.36° ± 5.67° for PG; P <0.001) of the maxillary first molar was observed in the MG when compared with the PG.

CONCLUSIONS

Both devices were effective for Class II molar distalization. The miniscrew-anchored cantilever was able to control the side effects of mesialization in the incisors and premolars during distalization when compared with distalization with a pendulum appliance.

Для цитирования: Campos Cassio Bernard Alves, Vilanova Lorena, Alessio Junior Luiz Eduardo, Miranda Felicia, Garib Daniela, Henriques José Fernando Castanha. Dentoskeletal effects of molar distalization with miniscrew-anchored cantilever and pendulum appliance for Class II correction.. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. 2025. DOI: 10.1016/j.ajodo.2024.11.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.