Effect of temperature on fluidity of irrigation fluids.

de Freitas Fonseca M, Andrade C M, de Mello M J E, Crispi C P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Fluid overload is a major complication during surgical hysteroscopy and transurethral resection of the prostate. We evaluated the role of temperature on absorption of the irrigation solution (IRRSOL) in endoscopic surgery when warm fluids are used to minimize hypothermia.

METHODS

We measured the density and dynamic fluidity of five IRRSOLs (0.9% saline, Ringer's lactate, 1.5% glycine, 5% dextrose, and 2.5/0.54% sorbitol/mannitol) at three different temperatures (17°C, 27°C, and 37°C). Next, a hypothetical typical endoscopic resection surgery was defined as the reference: total IRRSOL absorption (750 ml), resection time (30 min), and IRRSOL temperature (17°C). On the basis of Poiseuille's law, we calculated new values for intravasation using the predetermined dynamic fluidity values at 27°C and 37°C to assess the influence of the IRRSOL temperature on intravascular absorption (under identical conditions) and then estimated the time to reach fluid overload at each temperature with both electrolyte and non-electrolyte IRRSOLs.

RESULTS

Density and fluidity varied with temperature. In these specific conditions, when the temperature of the IRRSOL was increased from 17°C to 37°C, the mean absorption rate was predicted to increase about 54% and the theoretical 'safe' duration of surgery decreased by ∼65%, for both electrolyte and non-electrolyte IRRSOLs. The reduction in the 'safe' duration of surgery averaged 21.1 min for non-electrolyte IRRSOL (reduced from 60.0 to 38.9 min) and 35.2 min when electrolyte IRRSOLs were used (reduced from 100.0 to 64.8 min).

CONCLUSIONS

Compared with cold fluids, isothermic IRRSOL may increase the risk of fluid overload because dynamic viscosity decreases at higher temperatures.

Для цитирования: de Freitas Fonseca M, Andrade C M, de Mello M J E, Crispi C P. Effect of temperature on fluidity of irrigation fluids.. British journal of anaesthesia. 2010. DOI: 10.1093/bja/aeq303.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.