MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00259-025-07394-w

Медицинская библиотека · European journal of nuclear medicine and molecular imaging · 2025

PET imaging with [¹¹C]CHDI-00485180-R, designed as radioligand for aggregated mutant huntingtin, in people with Huntington's disease.

Delva Aline, Koole Michel, Serdons Kim, Bormans Guy, Skinbjerg Mette, Khetarpal Vinod, Liu Longbin, Bard Jonathan, Doot Robert, Warner John H, Sathe Swati, Sampaio Cristina, Wood Andrew, Van Laere Koen, Vandenberghe Wim

Клиническое исследование I фазыСтатьяПеревод в очереди

Аннотация

PURPOSE: [11C]CHDI-00485180-R ([11C]CHDI-180R) is a novel PET radioligand developed to image aggregated mutant huntingtin (mHTT). Data from mouse models of Huntington's disease (HD) and biodistribution studies in healthy volunteers suggested that [11C]CHDI-180R is a promising candidate for in vivo determination of cerebral aggregated mHTT levels using PET. In the iMagemHTT study reported here, we investigated [11C]CHDI-180R kinetic properties and suitability to quantify aggregated mHTT in brains of people with HD (pwHD).

METHODS

A total of 12 pwHD (53.7 ± 6.9y, 5 M/ 7 F, Shoulson-Fahn stage 2) and 12 healthy controls (HC; six young [26.8 ± 3.2y], 2 M/ 4 F; six age-matched [53.7 ± 6.1y],2 M/ 4 F) were included. We conducted dynamic 90 min [11C]CHDI-180R PET imaging with arterial sampling and radiometabolite quantification, and delineated volumes of interest (VOIs) using individual 3D T1-MRI. We calculated total distribution volumes (VT) using 2-compartment modelling (2TCM) as well as Logan graphical analysis and determined distribution volume ratios relative to cerebellum (DVRCBL). We applied partial volume correction, and assessed test-retest variability in pwHD.

RESULTS

VT showed considerable intersubject variability among HC (VT(cortex) = 0.68 ± 0.22) and pwHD (VT(cortex) = 0.75 ± 0.26), without any regional significant differences between the groups. VT test-retest variability was high if test and retest scans were performed on the same day, but low (< 10%) if performed one week apart. DVRCBL showed significantly higher [11C]CHDI-180R relative binding in frontal, temporal, parietal, occipital and composite cortex VOIs (average increase 19.5 ± 6.1%) in pwHD than age-matched HC.

CONCLUSION

[11C]CHDI-180R VT showed high intersubject variability and relatively low signal-to-background ratio. However, significant differences were found between pwHD and HC using cerebellum as pseudo-reference region.

REGISTRATION: EudraCT 2018-001862-41 clinicaltrials.gov NCT03810898  https://clinicaltrials.gov/study/NCT03810898?term=NCT03810898&rank=1.

Для цитирования: Delva Aline, Koole Michel, Serdons Kim, Bormans Guy, Skinbjerg Mette, Khetarpal Vinod, Liu Longbin, Bard Jonathan, Doot Robert, Warner John H, Sathe Swati, Sampaio Cristina, Wood Andrew, Van Laere Koen, Vandenberghe Wim. PET imaging with [¹¹C]CHDI-00485180-R, designed as radioligand for aggregated mutant huntingtin, in people with Huntington's disease.. European journal of nuclear medicine and molecular imaging. 2025. DOI: 10.1007/s00259-025-07394-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.