MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/jns-07/10/0721

Медицинская библиотека · Journal of neurosurgery · 2007

Optic radiation tractography integrated into simulated treatment planning for Gamma Knife surgery.

Maruyama Keisuke, Kamada Kyousuke, Shin Masahiro, Itoh Daisuke, Masutani Yoshitaka, Ino Kenji, Tago Masao, Saito Nobuhito

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECT: No definitive method of preventing visual field deficits after stereotactic radiosurgery for lesions near the optic radiation (OR) has been available so far. The authors report the results of integrating OR tractography based on diffusion tensor (DT) magnetic resonance imaging into simulated treatment planning for Gamma Knife surgery (GKS).

METHODS

Data from imaging studies performed in 10 patients who underwent GKS for treatment of arteriovenous malformations (AVMs) located adjacent to the OR were used for the simulated treatment planning. Diffusion tensor images performed without the patient's head being secured by a stereotactic frame were used for DT tractography, and the OR was visualized by means of software developed by the authors. Data from stereotactic 3D imaging studies performed after frame fixation were coregistered with the data from DT tractography. The combined images were transferred to a GKS treatment-planning workstation. Delivered doses and distances between the treated lesions and the OR were analyzed and correlated with posttreatment neurological changes.

RESULTS

In patients presenting with migraine with visual aura or occipital lobe epilepsy, the OR was located within 11 mm from AVMs. In a patient who developed new quadrantanopia after GKS, the OR had received 32 Gy. A maximum dose to the OR of less than 12 Gy did not cause new visual field deficits. A maximum dose to the OR of 8 Gy or more was significantly related to neurological change (p < 0.05), including visual field deficits and development or improvement of migraine.

CONCLUSIONS

Integration of OR tractography into GKS represents a promising tool for preventing GKS-induced visual disturbances and headaches. Single-session irradiation at a dose of 8 Gy or more was associated with neurological change.

Для цитирования: Maruyama Keisuke, Kamada Kyousuke, Shin Masahiro, Itoh Daisuke, Masutani Yoshitaka, Ino Kenji, Tago Masao, Saito Nobuhito. Optic radiation tractography integrated into simulated treatment planning for Gamma Knife surgery.. Journal of neurosurgery. 2007. DOI: 10.3171/jns-07/10/0721.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.