Development of a new instrument to evaluate gait characteristics of individuals with Duchenne Muscular Dystrophy: Gait Assessment Scale for Duchenne Muscular Dystrophy, and its validity and reliability.

Aydın Yağcıoğlu Güllü, Alemdaroğlu Gürbüz İpek, Topuz Semra, Yılmaz Öznur

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with Duchenne Muscular Dystrophy (DMD) have gait disorders. Therefore, specific gait assessment tools are needed.

AIMS: The aim of this study was to develop a gait assessment instrument for DMD patients (DMD-GAS), and investigate its validity and reliability.

STUDY

DESIGN

The scale was developed considering the expert opinions which included 10 physiotherapists who had experience in the management of patients with DMD, and the Content Validity Index (CVI) was calculated. The final version of the DMD-GAS that was agreed upon the experts consisted of 10 items, and each item scored between 0 and 2. The intra-rater reliability was established by the video analysis of children with a 1-month interval and inter-rater reliability was determined by the scores of 3 physiotherapists.

SUBJECTS: The study included 56 patients with DMD.

OUTCOME MEASURES: The criterion validity was determined by investigating the relationship between the total score of the DMD-GAS and Motor Function Measure (MFM), 6 Minute Walk Test (6MWT), and the data obtained from GAITRite.

RESULTS

The CVI of the DMD-GAS was 0.90 (p < 0.05). The construct validity and internal consistency of the DMD-GAS were excellent as well as the intra- and inter-rater reliability (>0.90). Moderate-to-very strong correlations were found between the total score of the DMD-GAS and the MFM-total score (r = 0.78), 6MWT (r = 0.71), gait speed (r = 0.50), stride length (r = 0.56), and base of support (r = -0.70) (p < 0.01).

CONCLUSIONS

The results indicated that DMD-GAS was a reliable and valid instrument to determine gait characteristics of the patients with DMD in clinical settings.

CLINICAL TRIAL NUMBER: NCT05244395.

Для цитирования: Aydın Yağcıoğlu Güllü, Alemdaroğlu Gürbüz İpek, Topuz Semra, Yılmaz Öznur. Development of a new instrument to evaluate gait characteristics of individuals with Duchenne Muscular Dystrophy: Gait Assessment Scale for Duchenne Muscular Dystrophy, and its validity and reliability.. Early human development. 2023. DOI: 10.1016/j.earlhumdev.2023.105843.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.