MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s24144489

Медицинская библиотека · Sensors (Basel, Switzerland) · 2024

A Novel Method for Identifying Frailty and Quantifying Muscle Strength Using the Six-Minute Walking Test.

Zhang Yunjin, Morita Minoru, Hirano Tsunahiko, Doi Keiko, Han Xin, Matsunaga Kazuto, Jiang Zhongwei

СтатьяПеревод пока не подготовлен

Аннотация

The six-minute walking test (6MWT) is an essential test for evaluating exercise tolerance in many respiratory and cardiovascular diseases. Frailty and sarcopenia can cause rapid aging of the cardiovascular system in elderly people. Early detection and evaluation of frailty and sarcopenia are crucial for determining the treatment method. We aimed to develop a wearable measuring system for the 6MWT and propose a method for identifying frailty and quantifying walking muscle strength (WMS). In this study, 60 elderly participants were asked to wear accelerometers behind their left and right ankles during the 6MWT. The gait data were collected by a computer or smartphone. We proposed a method for analyzing walking performance using the stride length (SL) and step cadence (SC) instead of gait speed directly. Four regions (Range I-IV) were divided by cutoff values of SC = 2.0 [step/s] and SL = 0.6 [m/step] for a quick view of the frail state. There were 62.5% of frail individuals distributed in Range III and 72.4% of non-frail individuals in Range I. A concept of a WMS score was proposed for estimating WMS quantitatively. We found that 62.5% of frail individuals were scored as WMS1 and 41.4% of the non-frail elderly as WMS4. The average walking distances corresponding to WMS1-4 were 207 m, 370 m, 432 m, and 462 m, respectively. The WMS score may be a useful tool for quantitatively estimating sarcopenia or frailty due to reduced cardiopulmonary function.

Для цитирования: Zhang Yunjin, Morita Minoru, Hirano Tsunahiko, Doi Keiko, Han Xin, Matsunaga Kazuto, Jiang Zhongwei. A Novel Method for Identifying Frailty and Quantifying Muscle Strength Using the Six-Minute Walking Test.. Sensors (Basel, Switzerland). 2024. DOI: 10.3390/s24144489.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.