MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00003246-199109000-00007

Медицинская библиотека · Critical care medicine · 1991

Noninvasive optimization of left ventricular filling using esophageal Doppler.

Singer M, Bennett E D

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To confirm whether the descending aortic blood flow velocity waveform variable of flow time corrected for heart rate, measured using an esophageal Doppler transducer, can be used for noninvasive optimization of left ventricular (LV) filling.

SETTING

ICU and operating theater.

SUBJECTS: Forty-three mechanistically ventilated patients in the ICU or undergoing cardiothoracic surgery in whom a pulmonary arterial catheter was in situ.

INTERVENTIONS: LV preload was a) increased from hypovolemic states (pulmonary arterial occlusion pressure [PAOP] less than 8 mm Hg) by fluid challenge, b) decreased from normovolemic states (PAOP 10 to 15 mm Hg) by either iv nitrates or intravascular fluid loss, and c) decreased from heart failure or fluid overload states (PAOP greater than 20 mm Hg) by iv nitrates. No other maneuver was performed concurrently.

MEASUREMENTS AND MAIN

RESULTS

Descending aortic blood flow was measured by an esophageal Doppler transducer. Corrected flow time was calculated by dividing systolic flow time by the square root of the cycle time. PAOP and corrected flow time increased after fluid challenges in hypovolemic states, and decreased when LV preload was decreased from normovolemic states. However, when preload was decreased from overload states, PAOP always decreased, but the corrected flow time usually increased before any subsequent decrease. The greatest value of corrected flow time corresponded with the maximal stroke volume seen.

CONCLUSIONS

Esophageal Doppler measurement of aortic blood flow can be used for rapid, noninvasive optimization of LV filling in mechanically ventilated patients.

Для цитирования: Singer M, Bennett E D. Noninvasive optimization of left ventricular filling using esophageal Doppler.. Critical care medicine. 1991. DOI: 10.1097/00003246-199109000-00007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.