Pediatric exercise science · 2024
Validation and Calibration for Embedding Rating of Perceived Exertion Into High-Intensity Interval Exercise in Adolescents: A Lab-Based Study.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liu Yong, Williams Craig A, Weston Kathryn L, Duncombe Stephanie L, Malik Adam A, Barker Alan R
Аннотация
PURPOSE: Rating of perceived exertion (RPE) is a convenient and cost-effective tool that can be used to monitor high-intensity interval exercise (HIIE). However, no methodological study has demonstrated the validity of RPE in this context. Therefore, the aim of this study was to validate and calibrate RPE for monitoring HIIE in adolescents.
METHODS: RPE, heart rate (HR), and oxygen uptake (V˙O2) data were retrospectively extracted from 3 lab-based crossover studies, with a pooled sample size of 45 adolescents, performing either cycling-based or running-based HIIE sessions. Within-participant correlations were calculated for RPE-HR and RPE-V˙O2, and receiver operator characteristic curve analysis was used to establish RPE cut points.
RESULTS: The results showed that RPE-HR demonstrated acceptable criterion validity (r = .53-.74, P < .01), while RPE-V˙O2 had poor validity (r = .40-.48, P < .01), except for HIIE at 100% peak power (r = .59, P < .01). RPE cut points of 4 and 5 were established in corresponding to HR/V˙O2 based thresholds.
CONCLUSION: RPE has some utility in evaluating intensity during lab-based running or cycling HIIE in adolescents. Future studies should expand the validation and calibration of RPE for prescribing and monitoring HIIE in children and adolescents in field-based contexts.
METHODS: RPE, heart rate (HR), and oxygen uptake (V˙O2) data were retrospectively extracted from 3 lab-based crossover studies, with a pooled sample size of 45 adolescents, performing either cycling-based or running-based HIIE sessions. Within-participant correlations were calculated for RPE-HR and RPE-V˙O2, and receiver operator characteristic curve analysis was used to establish RPE cut points.
RESULTS: The results showed that RPE-HR demonstrated acceptable criterion validity (r = .53-.74, P < .01), while RPE-V˙O2 had poor validity (r = .40-.48, P < .01), except for HIIE at 100% peak power (r = .59, P < .01). RPE cut points of 4 and 5 were established in corresponding to HR/V˙O2 based thresholds.
CONCLUSION: RPE has some utility in evaluating intensity during lab-based running or cycling HIIE in adolescents. Future studies should expand the validation and calibration of RPE for prescribing and monitoring HIIE in children and adolescents in field-based contexts.